2 - Subpart O
Process Variable & Undesirable Events (29-67)
16
Other
Professional
09/16/2017

Additional Other Flashcards

 


 

Cards

Term
FSV
Definition

→  installed on outlets of all pressurized process vessels to prevent back flow

→ permits flow in only 1 direction (fm inlet to outlet)

 

Term
ESD
Definition
TSE =
Term
TSE
Definition
detect fire in close proximity to process components and are also connected to the ESD system to provide the same results as an ESD Shut-In occurrence
Term

• Production Process Equipment

• Compressors and Pumps

• Pipeline SDV

• All Wellhead SSVs

Definition

Within 45 seconds of an ESD activation the following 4 needs to shut in following:

Term
Level Safety High (LSH)
Definition
has failed to operate properly or is in By-Pass mode of operation if the Liquid Overflow condition occurs
Term

1. Operator opens a bypass valve around LCV

2. Level Control Valve (LCV) fails in open position

Definition
2 Common Causes of Gas Blowby:
Term
Gas Blowby
Definition
discharge of gas from a process component through a liquid outlet.
Term
Indirect Heated Component
Definition

- vessel or heat exchanger used to increase the temperature of a fluid by transfer of heat from another fluid, such as steam, hot water, hot oil, engine exhaust, or other heated medium.

Term
Direct Ignition Source (Fired Components)
Definition
point of sufficient temperature and heat capacity to ignite a combustible mixture such an an exposed surface, a flame or a spark
Term
Temperature Safety Elements (TSEs)
Definition
must be installed on all components
Term
ESD
Definition

Actuation of this must shutdown all Engine driven components, due to the TSEs melting or ASH detecting 60% of the LEL

Term

 

Emergency Support Systems (ESS)

Definition

Secondary protection from all detectable leaks and small gas

leaks in an inadequately ventilated area should be provided by 

Term

1. PSL

2. FSV 

Definition

- Primary protection from leaks of sufficient rate to create an abnormal operating condition within a pressure component should be provided by _____ sensor to shut off inflow & _____ to minimize backflow.

 

Term
PSL
Definition

________ sensor should be installed at the highest practical location on the component to the minimize the chances of

 

fouling by flow stream contaminants

Term
Level Control Valve (LCV)
Definition

Gas blow-by can be caused by failure of a liquid level control system or the inadvertent opening of a By-Pass Valve around a _________

Term
adequate vent system
Definition

primary protection from under-pressure in an atmospheric

component should be provided by an _________