Term
ASDS
Describe the design basis of ASDS. |
|
Definition
-Satisfy safe shutdown requirements. -Cladding temp limited to < 1500F. -Primary pressure < 1332# steam dome pressure. -Primary containment pressure < 62#. -Primary containment temperature low enough for NPSF for Torus as a water source. |
|
|
Term
|
Definition
-RPS is not part of ASDS. -Can insert control rods at ASDS by depressurizing the SCRAM air header. |
|
|
Term
ASDS
Describe coolant inventory control with ASDS. |
|
Definition
-Manual operation of SRVs (E,F,G,H). -Manual operation of 12 core spray pump. |
|
|
Term
ASDS
Describe decay heat removal from ASDS. |
|
Definition
-All supplied from TORUS. -Torus is suction supply for core spray. -Torus is where SRVs discharge to. -Torus cooled in Torus cooling mode. |
|
|
Term
ASDS
Describe transfer of power to ASDS. |
|
Definition
-Master switch supplies power to ASDS panel. -Must use seperate power switch on ASDS panel for each system (SRVs, 12EDG, MSIV outboards, CS, and RHR). -All interlocks and manual operation from control room are blocked. |
|
|