ASME Sec V API 570 study questions
ASME Section V
22
Other
Professional
05/19/2013

Additional Other Flashcards

 


 

Cards

Term
When performing NDE MT examination what is the minimum distance beyond the area to be cleaned and examined
Definition

Min distance of 1" shall be examined when performing MT

 

 Answer found

ASME V: T-741.1.b

Term
When performing PT examination what is the minimum distance beyond the area to be examined and cleaned
Definition

Min distance of 1" shall be examined when performing PT

 

Answer found

ASME Sec V: T-642.b

Term

When performing RT exam, what is the maximum pipe size for performing an ellipitical shot

(double-wall technique, double-wall view)

Definition

3 NPS

 

V T-271.2.b

Term
What is the minum range of a pressure gauge used during a pressure test (Multiplied by test pressure)
Definition

1.5

 

Sec V: T1031.a

Term
Whats the perred range of a pressure gauge used during a pressure test ( Multipled by test pressure)
Definition

2

 

Sec V: T-1031.a

Term
Whats the # of bend tests required to qualify a welder or welding operator in welding positions 1G-4G
Definition

2

 

Sec: V QW452.1.a

Term
What is the Minmum # of exposures to RT 360° of a weld using a double-wall technique, double-wall veiw ( elliptical shot)
Definition

2

 

Sec V: T- 271.2.b.1

Term
Whats the RT film Density Range- allowed for the weld & IQI when using a gamma ray source
Definition

2.0- 4.0

 

Sec V: T-282-1

Term
Whats the minimum # of exposures to RT 360° of weld using a double-wall technique, single-wall view
Definition

3

 

Sec V: T-271.2.a

Term
When using a shim under a hole-type IQI, What is the # of sides of the IQI that must be seen in the RT inage
Definition

3

 

Sec V: T-277.3

 

Term
Whats the Maximum range of a pressure gauge used during a pressure test ( Multiplied by test pressure)
Definition

4

 

Sec V: T-1031.a

Term
The standard temperature range for PTexam is
Definition

40-125°F

 

 

Answer found

ASME Sec V: T-652/653

Term
What is the maximum temperature for UT readings per ASME Section V
Definition

1000°F

 

V:SE-797 8.5

Term
What is the maximum temperature for magnetic particle testing
Definition

Whatever temp is recommened by the Manufacturer

 

 ASME Sec V: 731.c

Term
What is the minimum time an exaniner should be in a darkened area proir to using a black light for MT & PT exam
Definition

5 min

 

Sec V: T -676.4.b & T-77.2.b

Term
Whats the final interpretation of a PT exam after the application of developer (time range)
Definition

10-60 min's

 

Sec V: T-676-1

Term

Whats the Max calibration Intervalof a MT permanent Magnet Yoke

Definition

Daily

 

Sec V T-762.a

Term
Whats is the Max calibrating Interval for RT densitometer
Definition

90 days

 

Sec V: T-262.1

Term
What is the Max calibrating Interval for Electromagnetic MT yoke
Definition

1 year

 

Sec V: T-762.a

Term
Whats the interval for a visual examiner's eye exam
Definition

1 year

 

Sev V: T-923

Term
What is the max interval to calibrate a pressure gauge used in testing
Definition

1 year

 

Sec V : T-1061

Term
What is the Max calibrating Interval to check the light intensity of a black light used in MT & PT exam
Definition

before and after use

 

Sec V: T-676.4.e & T-777.2.e