Term
According to Van Tasell, a hearing loss of cochlear origin with air-conduction thresholds less than ____ dB HL, is consistent with damage to the outer hair cells. |
|
Definition
|
|
Term
Which of the following is not considered a significant perceptual consequence of mild/moderate hearing loss? |
|
Definition
change in temporal resolution |
|
|
Term
Is spectral or temporal resolution of speech more important for intelligibility? |
|
Definition
|
|
Term
For contextually rich speech material (continuous discourse), 100% correct speech recognition performance can be achieved with an Articulation Index (AI) as low as |
|
Definition
|
|
Term
Quality control, physical fit, and performance comprise the _______________ stage of the hearing aid fitting process |
|
Definition
|
|
Term
The use of _____________ is the primary and preferred method of verifying the performance of hearing aids. |
|
Definition
|
|
Term
For what scale does the patient help determine specific communication settings in evaluating aided goals and performance. |
|
Definition
|
|
Term
Which speech recognition test would most likely be the best predictor of real-world speech understanding in noise |
|
Definition
|
|
Term
what would require the fewest number of conversions in derive real-ear fitting targets: |
|
Definition
thresholds in SPL measured at the eardrum |
|
|
Term
Different gain prescriptions have been shown to produce significant differences in intelligibility. T/F |
|
Definition
|
|
Term
If verification findings are excellent, validation of the fitting does not need to occur. T/F |
|
Definition
|
|
Term
For individuals with sensorineural hearing loss, aided and unaided speech understanding deficits in noise are likely due to a combination of inaudibility and suprathreshold deficits. T/F |
|
Definition
|
|
Term
Due to their smaller ear canals, all other things being equal, the output measured in a child's ear canal while wearing a hearing aid is likely higher than that measured in an adult's. T/F |
|
Definition
|
|
Term
Linear processing is always used in conventional hearing aids. T/F |
|
Definition
|
|
Term
With linear processing, peak clipping is always used for output limiting. T/F |
|
Definition
|
|
Term
Whether linear or WDRC processing will be used for a given patient will depend on: |
|
Definition
|
|
Term
The advantages of a binaural hearing aid fitting (assuming bilateral, symmetric hearing loss) include: |
|
Definition
performance in noise, localization, auditory deprivation |
|
|
Term
The Coupler Response for Flat Insertion Gain (CORFIG): |
|
Definition
can be applied to real-ear insertion gain targets to determine individual-specific coupler targets, requires incorporation of a correction factor based on hearing aid style, requires RECD data in order to be calculated |
|
|
Term
NAL-R is an appropriate fitting strategy for a hearing aid incorporating WDRC processing. |
|
Definition
|
|
Term
There is sufficient evidence to suggest that one particular prescriptive strategy is superior to others for most patients. |
|
Definition
|
|
Term
Part of the loudness equalization rationale is to normalize overall loudness while equalizing loudness across frequency bands. |
|
Definition
|
|
Term
If the manufacturer provides a proprietary fitting strategy for a given device, use of a device independent strategy should not be considered. |
|
Definition
|
|
Term
The hearing aid prescription that generates the highest predicted speech intelligibility, as determined via the articulation index, always yields the highest speech intelligibility and sound quality. |
|
Definition
|
|
Term
Fitting strategies based on a loudness normalization rationale have been shown to provide the highest sound quality in most environments. |
|
Definition
|
|
Term
If performed appropriately and consistently, loudness scaling tasks are reliable. |
|
Definition
|
|
Term
For probe microphone and test box measures, signal choice can have an impact on aided output. |
|
Definition
|
|
Term
To determine a multichannel hearing aid's maximum output at any given frequency, a 90 dB speech input should be used. |
|
Definition
|
|
Term
The noise reduction algorithm should never be turned off during ANSI measurements. |
|
Definition
|
|
Term
As long as the equalization data is stored, the patient can move during real-ear testing. |
|
Definition
|
|
Term
The depth of the probe microphone in the ear canal can impact both unaided and aided output. |
|
Definition
|
|
Term
The AV subscale score on the APHAB typically improves significantly after a hearing aid fitting. |
|
Definition
|
|
Term
Which prescriptive strategy incorporates a hearing loss "desensitization" factor? |
|
Definition
|
|
Term
To minimize the effect of a noise reduction alogrithm during verification, the test signal should have speech-like temporal and spectral characteristics |
|
Definition
|
|
Term
Verification using real-ear insertion gain can help account for an unusual REUR |
|
Definition
|
|
Term
Which prescriptive strategies are designed for fitting linear hearing aids |
|
Definition
|
|
Term
Which factors can have an impact on the output measured from a hearing aid in the test box or patient's ear? |
|
Definition
length of release time, number of channels, digital noise reduction, test signal |
|
|
Term
Sufficient evidence exists to state that directional microphone technology provides benefit for most hearing aid users in background noise. |
|
Definition
|
|
Term
Sufficient evidence exists to state that digital signal processing alone significantly increases speech intelligibility in all types of background noise. |
|
Definition
|
|
Term
Digital noise reduction is more effective for steady state, environmental noises as opposed to speech noise. |
|
Definition
|
|
Term
All potential hearing aid users require hearing aids that incorporate signal processing to reduce background noise. |
|
Definition
|
|
Term
A large vent can reduce the effectiveness of a directional microphone. |
|
Definition
|
|
Term
The long-term spectrum and amplitude of background noise is always different from the target speaker. |
|
Definition
|
|
Term
Microphone mismatch will decrease the effectiveness of a directional microphone. |
|
Definition
|
|
Term
The automatic program selection feature available on some high end products will select the program the user deems appropriate 99% of the time. |
|
Definition
|
|
Term
Feedback reduction on advanced digital products is accomplished by reducing overall gain at all frequencies whenever feedback is detected. |
|
Definition
|
|
Term
A hearing aid incorporating noise reduction via directional microphones and advanced signal processing will likely perform better than a hearing aid with only one of these options. |
|
Definition
|
|
Term
If both devices have an omnidirectional microphone only, a CIC hearing aid will demonstrate greater directionality than a BTE hearing aid. |
|
Definition
|
|
Term
A "compensated" or "equalized" response can often be chosen in order to make up for the loss of high frequency gain that naturally occurs in the directional mode. |
|
Definition
|
|
Term
Adaptive directionality has been shown to be superior to fixed directionality in most situations with background noise. |
|
Definition
|
|
Term
Subjective findings on the benefit of digital noise reduction are generally better than objective findings |
|
Definition
|
|
Term
Hearing aids with automatic directionality are generally not indicated for individuals with cognitive or dexterity issues. |
|
Definition
|
|
Term
Directional microphones should not be used with open style fittings since they will not be effective. |
|
Definition
|
|
Term
For what environments/situations would directional microphones lose their effectiveness |
|
Definition
highly reverberant environment, noise coming from behind the speaker |
|
|
Term
Deficits in frequency resolution will likely not impact an individual's aided ability to understand speech in noise. |
|
Definition
|
|
Term
If an individual has poor temporal resolution, he or she might have difficulty discerning speech sounds during briefs gaps in background noise. |
|
Definition
|
|
Term
An individual with hearing loss and complete recruitment and an individual with normal hearing would likley rate the loudness of high intensity sounds similarly. |
|
Definition
|
|
Term
All individuals with severe sensorineural hearing loss should be fitted with hearing aids using linear processing. |
|
Definition
|
|
Term
A single-channel hearing aid is likely appropriate for a mild to severe, sloping sensorineural hearing loss. |
|
Definition
|
|
Term
If hearing aids restore audibility of all speech sounds, the user will always demonstrate normal aided functioning. |
|
Definition
|
|
Term
Expansion should be used sparingly as it has a major impact on the audibility of conversational level speech. |
|
Definition
|
|
Term
The potential for auditory deprivation should be considered when deciding between a monaural versus a binaural hearing aid fitting. |
|
Definition
|
|
Term
For individuals with a conductive hearing loss, a medium level CT and CR around 2:1 is ideal. |
|
Definition
|
|
Term
Syllabic compression should be used with all patients with sensorineural hearing loss. |
|
Definition
|
|
Term
A compression ratio of 2:1 implies that |
|
Definition
for every 10 dB increase in input level, output increases by 5 dB. |
|
|
Term
A characteristic of a circuit employing compression limiting is a high compression threshold |
|
Definition
|
|
Term
With syllabic compression, the goal is to increase the amplitude of the consonant in relation to the vowel |
|
Definition
|
|
Term
If a hearing aid user's complaints point to high pitched sounds of high intensity being uncomfortably loud, the most sensible adjustment would be: |
|
Definition
increase in the high frequency channel compression ratio |
|
|
Term
If a hearing aid user's complaints point to high and low pitched sounds, from soft to high intensities, being too loud, the most sensible adjustment would be: |
|
Definition
|
|
Term
If you choose "increase gain for soft sounds" within the fitting software, what is most likely happening behind the scenes? |
|
Definition
gain and compression ratio are both increased |
|
|
Term
Would this be considered Wide-Dynamic-Range-Compression? CT = 30, CR = 2:1, attack time short, release time long |
|
Definition
|
|