Term
|
Definition
Flow or rate of flow of electrical charge through a conductor. Unit of measurement. AMP (A) |
|
|
Term
|
Definition
Electrons move around the circuit in one direction only. |
|
|
Term
|
Definition
Alternating Current changes direction. Electrons first move in one direction ,stop then flow in another |
|
|
Term
|
Definition
Unit of electric potential,the potential difference between 2 points on conductor carrying a current |
|
|
Term
|
Definition
|
|
Term
Resistors Connected in SERIES |
|
Definition
Current flows in turn through each of them. R1+R2+R3...etc =RESISTANCE TOTAL |
|
|
Term
|
Definition
Current passes through them at the same time,each provides its own circuit. 1/R1 + 1/R2 + 1/R3 = 1/TOTAL=Resistance total |
|
|
Term
|
Definition
is concerned with the relationship between I,V and R |
|
|
Term
|
Definition
Measured in WATT 1kw =1000watts Electric Power can be calculated by multiplying VOLTS x AMPS |
|
|
Term
Single Ring Circuit Should serve a floor area NO LARGER than |
|
Definition
|
|
Term
3AMP Fuses for appliances rated up to |
|
Definition
750watts (lamps ,clocks etc ) |
|
|
Term
13AMP Fuses for larger appliances rated up to .. |
|
Definition
|
|
Term
Preliminary Electrical Checks |
|
Definition
Check fuses for size n condition EARTH CONTINUITY TEST SHORT CIRCUIT TEST POLARITY TEST |
|
|
Term
Earth Continuity Test SET METER TO OHMS |
|
Definition
One test lead to Earth pin on the plug or first available earth connection.
Other test lead to each earth connection and appliance CASING/PIPEWORK/CONTROLS IN TURN
EACH RESISTANCE s/b LESS than 1 ohm |
|
|
Term
SHORT CIRCUIT TEST LIVE-NEUTRAL |
|
Definition
set to measure resistance =OHMS Connect test leads across main LIVE & NEUTRAL. Operate switches in their correct sequence. Meter measuring continuity=short circuit Should read NOT LESS than 10ohms |
|
|
Term
EARTH CONTINUITY TEST READING SHOULD BE |
|
Definition
|
|
Term
SHORT CIRCUIT TEST LIVE- NEUTRAL Reading S/B |
|
Definition
GREATER THAN 10. OHMS OPERATE ALL SWITCHES IN CORRECT SEQUENCE. READING LESS THAN 10 OHMS S/B INVESTIGATED |
|
|
Term
SHORT CIRCUIT TEST LIVE TO EARTH |
|
Definition
Ensures there is no electrical path between LIVE AND EARTH SHOULD READ O.L |
|
|
Term
|
Definition
Is a LOW RESISTANCE PATH between LIVE and NEUTRAL that allows an excess current to flow. |
|
|
Term
SHORT CIRCUIT CAN BE DETECTED BY |
|
Definition
Resistance testing provided CIRCUIT SWITCHES ARE OPERATED IN CORRECT ORDER (Current flows down the path of least resistance) |
|
|
Term
EARTH CONTINUITY TEST RESISTANCE OF THE EARTH PATH MUST BE AS LOW AS POSS...WHY? |
|
Definition
ELECTRICAL CURRENT WILL FLOW DOWN PATH OF LEAST RESISTANCE. A LOW RESISTANCE PATH WILL QUICKLY ALLOW A LARGE CURRENT TO FLOW,THIS WILL BLOW THE FUSE AND TERMINATE SUPPLY |
|
|
Term
POLARITY TEST/REVERSE POLARITY CHECKS CORRECT VOLTAGE MEASURED AT L,N AND EARTH CONNECTIONS |
|
Definition
PERFORMED WITH THE ELECTRICITY TURNED ON (Can only be done are prelim checks have been carried out) |
|
|
Term
POLARITY TEST/REVERSE POLARITY |
|
Definition
meter to VOLTS Connect Test leads between L and N (Reading should be 240v)
L and E (reading s/b 240v) N and Earth (reading s/b LESS than 15v) |
|
|
Term
|
Definition
A sacrificial protection of the circuit , it protects the circuit from an overloaded current. |
|
|
Term
|
Definition
In this type of system Neutral and protective functions (earth) are combined in a single conductor in part of the system. |
|
|