Term
why does the left ventricle have more muscle mass? |
|
Definition
it pumps against four times the pressure the right ventricle does |
|
|
Term
where does the blood pump to from the left ventricle? |
|
Definition
|
|
Term
where does the blood pump from the right ventricle |
|
Definition
|
|
Term
blood pressure in the aortic arch (#) |
|
Definition
|
|
Term
blood pressure in the pulmonary artieries (#) |
|
Definition
|
|
Term
|
Definition
aortic valve, pulmonary valve |
|
|
Term
atrio-ventricular valves (2) |
|
Definition
mitral/bicuspid valve, tricuspid valve |
|
|
Term
|
Definition
between left atrium and left ventricle |
|
|
Term
|
Definition
between right atrium and right ventricle |
|
|
Term
initiation point of electrical signal in the heart |
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
between right ventricle and right atrium |
|
|
Term
|
Definition
bundle of His break apart into individual fibers that carry the electrical signal that tells the ventricles to contract |
|
|
Term
|
Definition
depolarization of the myocardium (atrium) |
|
|
Term
|
Definition
contraction of the ventricular muscle |
|
|
Term
where on EKG is repolarization of atrium? |
|
Definition
hidden by the QRS complex |
|
|
Term
|
Definition
repolarization of ventricle |
|
|
Term
coronary artery supplies blood to.... |
|
Definition
|
|
Term
circumflex vessel, location and what does it supply? |
|
Definition
wraps around the heart, supplies myocardium (except not so much left ventricle) with blood |
|
|
Term
when is coronary flow higher? systole or diastole? |
|
Definition
|
|
Term
where do coronary arteries originate? |
|
Definition
|
|
Term
what happens to coronary arteries in systole? |
|
Definition
pressure and resistance increase, vessels almost close |
|
|
Term
what happens to coronary arteries in diastole? |
|
Definition
pressure decreases, but so does resistance, and flow increases |
|
|
Term
|
Definition
closed loop diagram describing the pressure and volume changes of the heart |
|
|
Term
|
Definition
contraction of the ventricles without any increase or decrease in volume |
|
|
Term
|
Definition
systolic contraction, release of blood into aortic arch |
|
|
Term
|
Definition
diastole, the ventricles are relaxing, but no volume is entering - atrio-ventricular valves are still closed |
|
|
Term
|
Definition
physical work done by the chamber during contraction |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
velocity in which the heart muscles contract |
|
|
Term
effect of increased HR on stroke volume |
|
Definition
can decrease stroke volume, not enough time to fill |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
ventricular bypass, prone to clogging, temporary assist device |
|
|
Term
Mechanical Auxiliary Ventricle |
|
Definition
device is relaxed during systole, contracted during diastole, used the concept of counter pulsation or diastolic augmentation, not used anymore, must be monitored with EKG and with every cardiac cycle |
|
|
Term
diastolic augmentation/counter pulsation |
|
Definition
device is relaxed during systole, blood can flow freely through aorta, closes up during diastole, forcing blood back into aortic arch. Blood stopped by semilunar valve, but it forced into the coronary arteries, supplying the weakened heart a larger blood supply, reduces amount of work heart has to do |
|
|
Term
Intra-aortic balloon pump |
|
Definition
uses concept of counter pulsation or diastolic augmentation, balloon in aortic arch or large arteries, inflates during diastolic to feed coronary arteries |
|
|
Term
insertion location of intra-aortic balloon pump |
|
Definition
|
|
Term
why don't drugs work in cardiac failure? |
|
Definition
vasodilators - decrease resistance, but perfusion plummets vasoconstrictors - increase pressure, increase flow, but you make a weak heart work harder |
|
|
Term
why did the cannula - diastolic augmentation technique fail? |
|
Definition
hemolysis of red blood cells, when moving that fast through a small opening, they get torn apart and aren't functional |
|
|
Term
series cardiac assist devices |
|
Definition
diastolic augmentation, ventricular bypass |
|
|
Term
external counter pulsation |
|
Definition
suit that covers bottom half of patient, decrease and increase pressure with the heart cycle |
|
|
Term
|
Definition
put a device around aorta, compress and release - can cause rupture and other damage to the aorta |
|
|
Term
|
Definition
body acceleration sync with heart - accelerates body with cardiac cycle, developed in holland, liked because it was non invasive..... |
|
|
Term
refractory ventricular failure |
|
Definition
failure that does not respond to medications |
|
|
Term
|
Definition
clinical phenomena - sweating, urinary output down, pulse bad |
|
|
Term
|
Definition
|
|
Term
indication of heart failure/need of assist device |
|
Definition
refractory ventricular failure cardiogenic shock unstable refractory angina impending infarction mechanical complicatsion ue to infarction ischemia related intractable ventricular arrhythmias septic shock angiography/angioplasty patients |
|
|
Term
reasons you can't get an assist device |
|
Definition
aortic insufficiency - counter pulsation will go through valve, damaging aneurym - weakened walls of aorta, increased pressure could burst the walls calcification - vessel is fragile and can break |
|
|
Term
reasons sheathless insertion of balloon assist device cannot be done |
|
Definition
severe obesity scarring of the groin |
|
|
Term
why do we increase diastolic pressure |
|
Definition
to increase coronary perfusion |
|
|
Term
dangers of increasing end diastolic pressure |
|
Definition
in effort to counter the weak contractions, the heart tries to increase the troke volume of the heart by filling it more. this larger fill can stretch the heart to the point where the interaction between the actin and myosin can no longer happen |
|
|
Term
what happens at the dicrotic notch? |
|
Definition
aortic valve loses, diastole begins |
|
|
Term
what peak increases in the cardiac pressure waveform when diastolic augmentation is utilized? |
|
Definition
diastolic peak is increased to well above the pressure in the systolic peak |
|
|
Term
what is the relationship between balloon assist device location and functionality |
|
Definition
direct - the closer it is the the heart, the more effective it is |
|
|
Term
|
Definition
phasing means syncing the function of the device up with the cardiac cycle, often times special algorithms are used to predict the changing of the heart rates |
|
|
Term
why don't these devices work as well in patients with healthier hearts |
|
Definition
the healthier the heart, the more capable it is to make compensatory changes, will try to correct the increased diastolic pressure |
|
|
Term
benefits of diastolic augmentation assist device |
|
Definition
reduce oxygen comsumption of left ventricle - not working as hard increase oxygen availability |
|
|
Term
navier - stokes and continuity equations |
|
Definition
fr incompressible fluids - newtons second law needed to analyze the blood flow |
|
|
Term
inflation/deflation time vs. oxygen availability graph |
|
Definition
surface graph - peak/highest point on the graph is highest oxygen availability |
|
|
Term
inflation/deflation time vs. oxygen consumption graph |
|
Definition
surface graph - peak/highest point on the graph is highest oxygen consumption |
|
|
Term
desired relationship between oxygen availability and oxygen consumption |
|
Definition
highest oxygen availability, and lowest oxygen consumption -- min and max do not occur at the same moment, develop an algorithm to optimize relationship |
|
|
Term
|
Definition
|
|
Term
|
Definition
|
|
Term
why is an MDP PSP graph used instead of Oa and Oc? |
|
Definition
easier to measure pressure than oxygen availability |
|
|
Term
|
Definition
constants used to normalize MDP and PSP values, then values are subtracted to find a performance index.
I = K1*MDP - K2*PSP |
|
|
Term
oxygen vs. contractility graph -- unassisted vs. assisted |
|
Definition
unassisted, there is oxygen deficit, assisted, there is larger reserve of oxygen |
|
|
Term
role of contractility in reserve volume of oxygen |
|
Definition
the lower the contractility, the lower the reserve |
|
|
Term
|
Definition
narrowing of blood vessels |
|
|
Term
in series assistance increases crossover point between what and what? |
|
Definition
oxygen availability and oxygen consumption - moves point to the left - higher Oa at lower contractility |
|
|
Term
inflation of balloon at end systole maximizes and minimizes what? |
|
Definition
maximizes SV, Voa; minimizes Voc |
|
|
Term
|
Definition
BYPASS the ventricle - ventricle has to pump less hard -- pumps from atrium to the aorta |
|
|
Term
|
Definition
left ventricular assist device |
|
|
Term
in series vs. parallel assist devices |
|
Definition
heart must retain pumping ability for in series in parallel, pump does nearly all work of the heart |
|
|
Term
parallel assist effects on coronary arteries |
|
Definition
not as much blood pumped into coronary arteries, but not as necessary, due to relieving heart of much work |
|
|
Term
in parallel assist, is the ventricle expected to recover? |
|
Definition
|
|
Term
exterior device - location, pros/cons |
|
Definition
device in abdomen, lines go from outside of the body to inside, risk of infection |
|
|
Term
interior device - location, pros/cons |
|
Definition
device in abdomen, internally supplied, foreign object attack, immune system response |
|
|
Term
why don't parallel assist devices have to be synced to the heart? |
|
Definition
heart works so feebly to begin with, not necessary |
|
|
Term
|
Definition
1950's artificial heart in animals (air pump) |
|
|
Term
first implantation in human - TAH, pros/cons |
|
Definition
total artificial heart - intended as a bridge to transplantation patient lived for two days - died of stroke |
|
|
Term
|
Definition
enormous concept next to the bed air pumped heart barney clark - survived 112 days |
|
|
Term
|
Definition
first recipient of the Penn State Heart |
|
|
Term
Abiocore Artificial Heart |
|
Definition
|
|
Term
why didn't cannulation work? |
|
Definition
|
|
Term
LVAD implant approved by FDA |
|
Definition
|
|
Term
non-pulsatile implant properties |
|
Definition
centrifugal, axial flow necessary properties: small, simple design, no valves, longer life, less invasive surgery, electrically driven, smaller transcutaneous lines |
|
|
Term
non-pulsatile implant complications |
|
Definition
bleeding, thromboembolism, increased gastro-intestinal bleeding, inreased platelet damage, hemolysis, ventricular arrythmia |
|
|
Term
|
Definition
first LV assist device, 1966 three tubes, one afferent, one efferent, and one pumps the diaphragm |
|
|
Term
|
Definition
parallel assist device, external air power supply, pneumatic |
|
|
Term
|
Definition
first generation pneumatic pump |
|
|
Term
|
Definition
inserted into the left ventricle, draws blood from LV and into aorta, INSIDE THE BODY |
|
|
Term
|
Definition
improved from jarvik 7, transcutaneous connection to battery power |
|
|
Term
|
Definition
|
|
Term
|
Definition
internal rechargeable battery, external coil and implanted coils right underneath the skin |
|
|
Term
|
Definition
made of titanium and stainless steel inflow - LV outflow - aorta |
|
|
Term
|
Definition
cannul from bottom of the ventricle, pumped up probe to the aorta |
|
|
Term
|
Definition
minimal surgery - placed endovascularly implantable control and battery - increase pump efficiency, eliminate transcutaneous wires pulsatile or continuous flow? automatic speed control preventing retrograde flow during weaning - can lead to rapid patient deterioration |
|
|
Term
Medtronic tilting disc valves |
|
Definition
failed, caused thromboembolism, in jarvik 7 |
|
|
Term
|
Definition
survived on Jarvik 7 for 620 days |
|
|
Term
Dr. Alain Carpentier artificial heart |
|
Definition
made of animal biosynthetic tissues, ventricles are equipped with micropumps |
|
|
Term
benefits of non-pulsatile hearh |
|
Definition
simpler, smaller, more reliable, no need for valves - less RBC damage, lower energy requirement, easier to implant |
|
|
Term
|
Definition
10 liters/min flow rate 70-120 bpm accelerate blood from 0-25 lpm on one beat pump against 120mmHg filling pressure 20mmHg |
|
|
Term
design requirements LV assist |
|
Definition
10 years or more must operate continuously maintenance free components small and strong efficient power - implantable of delivered across skin responsive to biological demands |
|
|
Term
anatomical considerations |
|
Definition
must operate in adults and children stable, no corrosion no degradation in emzymatic attack capable of being joined to flexible anatomy must not damage anatomical structures anatomy must be able to support the heavy device |
|
|
Term
|
Definition
not used anymore - ball covers opening in diastole, caused clotting and hemolysis, disruption of flow |
|
|
Term
Magovern-Cromie sutureless valve |
|
Definition
small hooks around the rim angled to the side - lowers valve into plae |
|
|
Term
|
Definition
shrinking the size of the ball in the valve - decrease obstruction of ball, smaller cage on other side to make sure ball goes through the valve back |
|
|
Term
single leaflet disc valves |
|
Definition
worse than ball valve, disrupted flow more |
|
|
Term
|
Definition
tilting disc valve with a single disk - held in place by an inflow and outflow strut |
|
|
Term
|
Definition
developed cracks, struts would fail and disk would separate and create an embolism |
|
|
Term
|
Definition
poor test results in the US, two flaps that pivot on a hinge |
|
|
Term
|
Definition
silicone rubber silicone carbide pyrolitic carbion |
|
|
Term
|
Definition
animal tissue valves - porcine or bovine non valve tissue bovine pericardium stentless human tissue valves from another person or autograft - take pulmonary valve to use as a replacement |
|
|
Term
|
Definition
hancock valves (porcine) standard and modified, carpentier-Edwards valves |
|
|
Term
|
Definition
single pig valve sewm onto plastic stent |
|
|
Term
|
Definition
composite of two porcine valves |
|
|
Term
|
Definition
ionescu-shiley, hancock, carpentier-edwards - securing pericardial tissue to the stent to avoid high stress regions that lead to tears aortic valve - pericardial sac |
|
|
Term
|
Definition
eliminate space taken up by stent |
|
|
Term
|
Definition
pros: excellent hemodynamics decrease in thickness of heart cons: more difficult to implant requires special measurements no data on durability |
|
|
Term
|
Definition
valve transplanted form another person |
|
|
Term
|
Definition
transplanted from one position to another within the same person |
|
|
Term
|
Definition
pulmonary valve to replace aortic valve |
|
|
Term
|
Definition
infection of the heart muscle |
|
|
Term
|
Definition
heart rhythm disorder - partial block in AV node, slows heart rate, depolarization signals slow to 30-40 bpm |
|
|
Term
|
Definition
signal does not get from atrium to ventricle |
|
|
Term
|
Definition
|
|
Term
|
Definition
atria fibrillation - not as deadly |
|
|
Term
|
Definition
ventricular fibrillation - cannot survive for very long |
|
|
Term
pacemaker original design |
|
Definition
for people with complete heart block, fixed rate |
|
|
Term
|
Definition
one lead, titanium case is used as other electrode |
|
|
Term
pacing cells - killing a group of cells. How/why? |
|
Definition
current density diminishes, has to travel further. If it decreases, increase the amplitude. ALSO additional drain of battery |
|
|
Term
|
Definition
Chamber paced, first letter V,A,D (ventricle, atrium, dual) Chamber Sensed V,A,O (ventricle, atrium, none) Mode of Response T,I,O (triggered, inhibitied, none) |
|
|
Term
|
Definition
Addition of programmable functions R,C,M,P,O (rate modulated, communicating, multiprogrammable, simple programmable, none) Antitachycardia functions P,S,D,O (paced, shocks, dual, none) |
|
|
Term
communicating letter code |
|
Definition
atria and ventricles synchronized |
|
|
Term
|
Definition
lose 10% of blood flow of atrium |
|
|
Term
|
Definition
SA node not functioning correctly, AV node is fine |
|
|
Term
|
Definition
pace atrium and ventricle in sync |
|
|
Term
|
Definition
if signal, no pacing, if no signal, paces |
|
|
Term
|
Definition
|
|
Term
|
Definition
amplitude duration refractory period atrial sensitivity pacing rate AV delay pacing mode |
|
|
Term
|
Definition
zinc mercury cells - projected to last for 5 year, lasted for 2 current: lithium iodide 10-12 yrs life
future: biological batteries |
|
|