Term
Which type of APU is on the CL605? |
|
Definition
|
|
Term
What is the size of the APU generator (electrical output)? |
|
Definition
30kva, 400hz, 3 cycle AC generator |
|
|
Term
Where does the APU get fuel? |
|
Definition
Normal - Right tank Backup - Left engine fuel feed manifold (neg-g) |
|
|
Term
How is the APU generator adapter oil cooled? |
|
Definition
Fuel/Oil heat exchanger uses fuel from right main tank |
|
|
Term
What type of signal does the APU receive for automatic and manual shutdowns? |
|
Definition
Overspeed signal (107%) closes fuel control unit's solenoid shutoff valve |
|
|
Term
When is Neg G fuel utilized? |
|
Definition
Neg G condition exists APU pump fails |
|
|
Term
What closes the APU Neg G shutoff valve? |
|
Definition
|
|
Term
What is the time limit when the APU fuel pump is inop? Why? |
|
Definition
10 min Neg G fuel does not cool APU generator adapter oil |
|
|
Term
What powers the APU fuel pump? |
|
Definition
|
|
Term
What is the amp hour rating of the APU battery? Main battery? |
|
Definition
APU - 43 amp hour Main - 17 amp hour |
|
|
Term
What is the min voltage required for APU start? |
|
Definition
22 volts for each battery |
|
|
Term
Where does the ECU receive its power (primary/secondary)? |
|
Definition
Primary - Battery Bus Secondary - APU Battery Direct Bus |
|
|
Term
When does the ECU use secondary power? |
|
Definition
When primary voltage drops below 22v |
|
|
Term
|
Definition
Monitors APU sensors and switches Sets fuel and temp schedules Adjusts fuel supply to maintain constant RPM at 100% Sends data to EICAS and APU Fault panel |
|
|
Term
How is the APU starter motor powered? |
|
Definition
|
|
Term
When is APU ignition started/stopped? |
|
Definition
Start - Start/Stop pressed and 5% RPM Stop - 99% RPM |
|
|
Term
What happens when the Power Fuel switch is selected? |
|
Definition
Powers APU ECU after 3 sec bite test Opens APU and Neg G shutoff valves Energizes APU fuel pump EGT and RPM gauges on EICAS page |
|
|
Term
What happens when the APU Start/Stop switch is selected? |
|
Definition
5% - Fuel and ignition 35%-45% - Starter cutout 95% 4 sec - APU Avail 99% - Ignition deactivated 100% 15 sec - APU Gen Off msg 2 min - Bleed loads |
|
|
Term
Why do you wait until all EICAS indications are removed before turning the battery master off? |
|
Definition
Allows ECU time to complete shutdown functions and power down |
|
|
Term
What are the auto-shutdowns of the APU? |
|
Definition
Fire, Overspeed/Underspeed, Overtemp Low oil pressure, Gen adapter low oil pressure High oil temp, Gen adapter high oil temp, Loss of EGT sensor, ECU failure |
|
|
Term
When does the APU SCV (surge control valve) operate? Why? |
|
Definition
High altitudes to prevent compressor surges 15,000'-20,000' |
|
|
Term
Where is bleed air indication displayed? |
|
Definition
EICAS summary page is the only place (also fuel temp and bulk fuel temp) |
|
|
Term
|
Definition
Valve has failed in open position APU LCV interlock activated |
|
|
Term
"APU SOV" and "APU NEG-G SOV" caution |
|
Definition
Valve open with APU FIRE PUSH or does not match APU PWR FUEL position within 5 seconds |
|
|
Term
|
Definition
Fuel and Neg G shutoff valves have closed after APU FIRE PUSH sw/lt is pushed |
|
|
Term
When will the APU green "AVAIL" light come on? |
|
Definition
|
|
Term
How do you confirm the cause of an APU shutdown? |
|
Definition
APU trip indications on the APU fault panel |
|
|
Term
How is the APU protected by fire? |
|
Definition
Auto-shutdown Detection system Firex bottle |
|
|