Shared Flashcard Set

Details

Condensate Demineralizer (Con Demin)
BWR Systems
12
Other
Not Applicable
07/09/2012

Additional Other Flashcards

 


 

Cards

Term
Con Demin

Describe the power supply for the Con Demin system.
Definition
-Everything is powered by MCC-151.
-MCC-151 is normally supplied by MCC-121.
-MCC-151 alternate supply is MCC-131.
-The ATS for MCC-121 to MCC-131 is normal seeking.
Term
Con Demin

Describe the flow balance monitors on C-80 border colors and signifigance.
Definition
-Yellow: Not in the range of flow balancing equation.
-Green: In the flow balancing equation.
-Red: Lead vessel in the flow balance equation.
Term
Cond Demin

Describe the purpose of the master flow controller.
Definition
Operates to equalize system flow through each of the units in service.
Term
Con Demin

Discuss the control room alarms for Con Demin.
Definition
-Cond demin bypass valve open.
-Cond demin trouble alarm.
Term
Con Demin

Describe the high vessel D/P setpoint.
Definition
7.5 psid.
Term
Con Demin

Describe the basket strainer setpoint.
Definition
12 psid.
Term
Con Demin

Describe the flow balance overide setpoint and what happens.
Definition
-45 psid.
-Opens the demin basket strainer outlet valves for any that are in auto to lower d/p across the demineralizers.
Term
Con Demin

Describe the bypass valve open setpoint.
Definition
50 psid system pressure.
Term
Con Demin

Describe the 2nd bypass open pressure.
Definition
52 psid system pressure.
Term
Con Demin

Describe when the holding pump starts.
Definition
1250 gpm.
Term
Con Demin

Describe the high effluent conductivity alarm.
Definition
0.08 us/cm.
Term
Con Demin

Describe the influent high conductivity setpoint.
Definition
0.10 us/cm.