Term
Alternate Shutdown
Definition
Fire not in control
Term
3l
Definition
Dedicated Shutdown
Term
Dedicated Shutdown
Definition
fire in control
Term
Where can CTG 11 be operated
Definition
Dedicated shutdown panel(BOP switch gear room), locally, control
Term
CTG trip
Definition
<450F
Term
How do CTGs start
Definition
2,3,4 AC motor #1 Diesel starts CTG 1 with battery power
Term
wait to start
Definition
1 min between starts
Term
CTG auto
Definition
takes CTG out of remote
Term
Where are CTG DCS controls at?
Definition
Control local 120kv mat rad waaste
Term
Turbine Overspeed
Definition
(5610 rpm electric)
Term
High Exhaust Temperature
Definition
(995/1015 base/peak units 2/3/4) / (unit 1-1090)
Term
Oil Pressure
Definition
(8 psi)
Term
Oil Temperature
Definition
(175ºF)
Term
HUR limt
Definition
100/hr
Term
CDR limit
Definition
100/hr
Term
SRV Lift high pressure(5)
Definition
1155#
Term
SRV Lift mid pressure(5)
Definition
1145#
Term
SRV Lift low pressure(5)
Definition
1135#
Term
ARI/RPT trip
Definition
1133#
Term
RPS Scram
Definition
1093#
Term
LLS setpoints
Definition
1017/1047#
Term
Pressure TS limit/Alarm
Definition
1045#
Term
MSIV Isolation
Definition
756 #
Term
CS and RHR Valve open permissive
Definition
461#
Term
SDC permissive
Definition
89.5#
Term
L8
Definition
214
Term
L7
Definition
201.7
Term
N
Definition
197
Term
L4
Definition
192.7
Term
L3
Definition
173.4
Term
L2
Definition
110.8
Term
L1
Definition
31.8
Term
TAF
Definition
0
Term
L0
Definition
-42
Term
100% Core Flow
Definition
100.0 x 106 lbm/hr.
Term
100% Prx thermal
Definition
3486
Term
L8 funtion
Definition
Trips HPCI & RCIC (WR), RFPT, Main Turb, F001 in SBFW (NR)
Term
L7 funtion
Definition
HI Level Alarm
Term
L4 funtion
Definition
Lo Level Alarm, Limiter 2
Term
L3 NR funtion
Definition
RPS Scram, Groups 4,13,15, ADS confirmation
Term
L2 WR funtion
Definition
LPCI Loop Select, HPCI/RCIC start, Recirc Trip (from ARI), CCHVAC to recirc, RBHVAC trip, SBGT starts, Groups 2,10,11,12,14,16,17,18, CAC Start
Term
L1 WR funtion
Definition
CS Starts, RHR starts, RHRSW trips, HPCI/RCIC Baro & vac pumps trip, ADS Timer, RB floor & eq drain sumps trips, DW cooling stop or low speed, Groups 1,3,5.
Term
L0 funtion
Definition
RHR torus cooling/spray, DW Spray isolates.
Term
Limiter No. 1(%)
Definition
30%
Term
Limiter No. 2(%)
Definition
37%
Term
Limiter No. 3(%)
Definition
37%
Term
Limiter No. 4(%)
Definition
75%
Term
Limiter No. 1(Initiation signal)
Definition
F031* not FO or <20% FW flow
Term
Limiter No. 2(Initiation signal)
Definition
Lose of one RFPT and L4
Term
Limiter No. 3(Initiation signal)
Definition
F026A/B closed (Htr drains) + 3sec
Term
Limiter No. 4(Initiation signal)
Definition
Other recirc pump TRIPped. Drive motor or field breaker open.
Term
Limiter No. 1(prevents)
Definition
Prevents RR pump cavitation & Axial Thrust
Term
Limiter No. 2(prevents)
Definition
Prevents L3 scram
Term
Limiter No. 3(prevents)
Definition
Prevents L3 scram
Term
Limiter No. 4(prevents)
Definition
Prevents JP/piping vibration
Term
ATWS/ARI
Definition
Term
Suction or Discharge Valve
Definition
<90%
Term
MG set high air temp
Definition
260
Term
MG set low oil press
Definition
30 #
Term
MG set high LO temp
Definition
210
Term
Recirc MG trips
Definition
ATWS/ARI Suction or Discharge Valve MG set high air temp MG set low oil press MG set high LO temp 65G under voltage MG set generator lockout