Term
How many hours does the CVR record?
Definition
2 hours.
Term
How do you erase the CVR?
Definition
Push ERASE with the Parking brake set
Term
What is the first flight of the day check for the CVR?
Definition
Press the TEST button and observe the light for 1 second.
Term
When do the engine driven generators come online?
Definition
At 57% N2.
Term
What is the output of an engine driven generator?
Definition
400 Amps; 28 Volts.
Term
What does GPU AVAIL mean?
Definition
GPU power is detected. Not necessarily acceptable power.
Term
What is the output of the APU generator?
Definition
400 Amps; 28 Volts. (300 Amps above 30,000 ft)
Term
What type of main batteries are installed ?
Definition
2 NiCads.
Term
What is the output of each main battery?
Definition
24 Volts; 44 Amps.
Term
How long will the main batteries last in an electrical emergency?
Definition

40 minutes.

Note: Can be increased to 45 minutes if you shut-off PITOT 3 heat

Term
How many APU start attempts are assumed in the 40 minutes of main battery power?
Definition
3
Term
If a main battery temperature exceeds +70C will it drop offline?
Definition
No, You will get an EICAS message.
Term
What does the ESSENTIAL POWER button do?
Definition
It forces the "electrical emergency" configuration. The main batteries are connected to the essential busses.
Term
When would you press the ESSENTIAL POWER button?
Definition

When directed by a checklist.

Example: ELEC ESS TFR FAIL procedure

Term
What is the definition of an electrical emergency?
Definition
Loss of all 5 generators in flight.
Term
What would the PFD, MFD and EICAS look like in an "electrical emergency?"
Definition
  • PFDs and MFDs - dark 
  • EICAS and RMUs - lit.
Term
What is an "electric essential transfer failure" (ELEC ESS XFER FAIL)?
Definition
The EDL failed to configure for an electrical emergency when required. The DC buses aren't isolated from the batteries and since it's an electrical emergency the batteries aren't being charged!
Term
What would the PFDs, MFDs and EICAS look like during an "electric essential transfer fail" (ELEC ESS XFER FAIL)?
Definition
Normal
Term
What are the main purposes of the central DC bus?
Definition
To connect the GPU and APU to the electrical system and to allow load sharing between the busses.
Term
How many generators need to be online to automatically power the shed busses?
Definition
3
Term
How can you power the shed busses with less than 3 generators online on the ground?
Definition
SHED BUSSES knob to OVRD.
Term
Can you power the shed busses with less than 3 generators online while in flight?
Definition
No
Term
What happens if you turn BUS TIES knob to the OFF position?
Definition
It opens the bus tie contactors regardless of any command from the electrical system logic.
Term
What happens when the BUS TIES knob is in the AUTO position?
Definition
The EDL controls the bus tie contactors.
Term
What happens when the BUS TIES knob is in the OVRD position?
Definition
The bus tie connectors close regardless of EDL unless one of the GCUs detects an over-current condition.
Term
What is an "electric emergency abnormal"?
Definition
The EDL configured for an electrical emergency when not required. The DC busses are isolated. Batteries supplying Central & Essential Busses and not being charged!
Term
In the case of an "electrical emergency abnormal" can you reconnect the 3 networks?
Definition
No. But you can start the APU to keep the batteries charging while they power the Central and Essential busses.
Term
How is the AC inverter powered?
Definition
DC Bus 1.
Term
What is the purpose of the back-up battery?
Definition
It provides stabilized power to the GCUs.
Term
When is the back-up battery connected to the electrical system?
Definition
  • BATT 1 - AUTO; and
  • BACKUP button - in.
Term
Can external power charge the back-up battery?
Definition
No
Term
How much power does the back-up battery provide?
Definition
24 Volts; 5 amps.
Term
Where is the back-up battery located?
Definition
In the floor in front of the F/O.
Term
Why do we deselect the back-up battery when "re-booting" the aircraft?
Definition
The back-up battery powers the EDL (Electrical Distribution Logic).
Term
When is the ground service bus powered?
Definition
  • GPU Connected
  • GPU button out
  • BATT 1 & 2 knobs OFF
Term
If the Flight Attendant turns the emergency lights on from the F/A panel, can they be turned off from the cockpit? 
Definition
No
Term
How long will the emergency light batteries last?
Definition
15 minutes.
Supporting users have an ad free experience!