Term
Pumper Fire Apparatus
Definition
The bread and butter of the fire service. The most common type of fire apparatus, it is a part of almost every fire department.
Term
750 GPM's, minimum of 300 gallons
Definition
Per NFPA 1901 a pumper must be equipped with a permanently mounted pump with a minimum rating of what? And a minimum of how many gallons in its water tank?
Term
35mph, and 25 seconds
Definition
From a standing start, the apparatus must be able to attain a speed of what? and within how many seconds on a level road?
Term
50mph
Definition
The apparatus must be able to attain a minimum top speed of what on a level road?
Term
20mph
Definition
The apparatus must be able to maintain a speed of at least what on any grade up to and including 6 percent?
Term
800ft of 2 1/2-inch or larger supply/attack hose
400ft of 1 1/2, 1 3/4, or 2-inch attack hose
One combination spray nozzles capable of delivering 200 GPM at a minimum
Two combination spray nozzles capable of delivering 95GPM at a m minimum
One play pipe, with shut-off and 1-inch 1 1/8-inch and 1 1/4-inch tips.
Definition
Per NFPA 1901 What following types of fire hose and nozzles are required on a pumper fire apparatus?
Term
one straight ladder with roof hooks, one extension ladder, and one attic ladder
Definition
What type of ladders and how many are on a Pumper fire apparatus?
Term
Initial attack fire apparatus
Definition
What apparatus is more maneuverable than the pumper and has four wheeled drive?
Term
Minimum rated capacity of 250GPM and a water with a minimum of 200 gal.
Definition
What is the minimum rated capacity of a Initial attack fire apparatus? and what is the minimum tank size?
Term
40 cubic foot
Definition
What is the minimum size enclosed weather resistant compartment on a pumper fire apparatus?
Term
-300ft of 2 1/2-inch or larger fire supply hose
-400ft. of 1 1/2 inch, 1 3/4 inch, or 2 inch attack fire hose
-Two combination spray nozzles with a minimum capacity of 95GPM.
Definition
What are the minimum fire hose and nozzles on a Initial Attach Fir Apparatus?
Term
22 cubic foot
Definition
What is the minimum weather resistant enclosed compartment on a Initial attack Fire Apparatus?
Term
12ft. or longer combination or extension type ladder.
Definition
What ladder is carried on a Initial attack fire apparatus?
Term
NFPA 1931
Definition
What NFPA is Standard for Manufactures Design of Fire department Ground Ladders?
Term
Chapter 16
Definition
If a Mobile water Supply Apparatus is equipped with a pump. It must meet the criteria in what chapter of NFPA 1901?
Term
20 Cubic Feet
Definition
What is the minimum enclosed compartment capacity on a Mobil water Supply Apparatus?
Term
115ft.
Definition
What is the minimum total complement of ground ladders that must be on a Aerial Fire apparatus?
Term
One attic ladder, two straight ladders with roof hooks, and two extension ladders.
Definition
What is the minimum number and type of ladders that must be on an Aerial fire apparatus according to NFPA 1901?
Term
40 cubic feet
Definition
What is the minimum enclose compartment space for a Aerial Fire Apparatus?
Term
Pump, Water tank, Fire hose storage, aerial, ground ladders
Definition
What are the five functions on a Quint?
Term
1000 GPM's, 300 Gal.
Definition
What is the pump rated capacity on a Quint? and what is the minimum water tank certified capacity?
Term
85ft.
Definition
What is the minimum total complement of ground ladders a Quint must hold?
Term
40 cubic feet
Definition
What is the minimum enclosed compartment storage on a Quint?
Term
120 cubic feet
Definition
What is the minimum enclosed compartment storage capacity on a Special Service Fire apparatus?