Term
Gas Rate Calculation Metric |
|
Definition
Gas Rate(m3/h)=(2nd read-1st read)x3600 --------------------- time Taken (seconds) |
|
|
Term
Heat Input Calculation Metric |
|
Definition
Heat Input(kW)=Gas Rate(m3/hr)x c.v(MJ/m3 ---------------------- 3.6 |
|
|
Term
|
Definition
by dividing by 3412 Where this is gross convert to net by divivding by 1.11 |
|
|
Term
Heat Input Calculation IMPERIAL |
|
Definition
Heat Input(btu/hr)=Gas Rate(ft3/hr)xC.V(btu/ft3) Average IMPERIAL C.V=1040btu/ft3
to covert btu/hr to kW divide by
3412 |
|
|
Term
|
Definition
Gas Rate=Seconds in 1 hour (3600) ----------------- Time Taken (Seconds) |
|
|
Term
|
Definition
Is the amount of heat produced by an appliance in a given time. |
|
|
Term
|
Definition
The quantity of gas used by an appliance |
|
|
Term
|
Definition
Total heat input:Not a mandatory check if you have undertaken the pressure check, however it does allow you to confirm that the correct injector has been installed in relation to the pressure. |
|
|
Term
Gas Calculation HEAT INPUT METRIC D.Q.M |
|
Definition
2nd-1st=gas x 30 gas x 30 x 10.7 /by 1.11 |
|
|
Term
|
Definition
|
|