Term
Where do we grind in stage 1 of occlusal equilibration? |
|
Definition
Centric holding area. NOT in fossa |
|
|
Term
Where do we grind in stage 2 of occlusal equilibration? |
|
Definition
|
|
Term
What is the order of eliminating interferences during occlusal equilibration? |
|
Definition
1 Non working 2 Cross Tooth 3 Working 4 Protrusive |
|
|
Term
Where are the three areas that may provide incisal guidance? |
|
Definition
Mandibular incisors Canines Mesial Inclines of First Mandibular Premolars |
|
|
Term
How much space between an impression tray and the teeth? |
|
Definition
|
|
Term
How many scoops of alginate for max and mand impressions? |
|
Definition
|
|
Term
What is the working time of type 2 regular set alginate? |
|
Definition
|
|
Term
How do hot and cold water affect setting times generally? |
|
Definition
Cold = retarder Hot = speed up |
|
|
Term
What is the definition of working time? |
|
Definition
From start of mixing to beginning of setting of material |
|
|
Term
Technically how long should PVS Adhesive dry on custom tray? |
|
Definition
|
|
Term
Impression stone to water ratio? |
|
Definition
100mL to 300 g powder (in preclinic it is 1 cup stone with 46 mL water) |
|
|
Term
How long do we vibrate bowl of stone? |
|
Definition
|
|
Term
What height of stone above the gingival margins for casts without a base? |
|
Definition
|
|
Term
How long should stone set? |
|
Definition
|
|
Term
Height of casts from base to occlusal table? |
|
Definition
|
|
Term
Height of cast/base at thinnest part? |
|
Definition
|
|
Term
How much "land" on sides of stone casts? |
|
Definition
|
|
Term
What kind of articulator do we have? |
|
Definition
|
|
Term
Should bite fork arm be on left or right of patient? |
|
Definition
|
|
Term
How high above the incisal edge of the central/lateral incisors is the anterior reference point (infraorbital notch) during the facebow transfer? |
|
Definition
43mm above right central or lateral incisor. |
|
|
Term
What are the measurements for Bennett angle and Condylar Inclination on our articulators? |
|
Definition
Bennett Angle = 15 degrees Condylar Inclination = 30 degrees |
|
|
Term
For the Putty Shell, how far past gingival margins should it extend? |
|
Definition
|
|
Term
Setting time for Putty Shell Aquasil? |
|
Definition
|
|
Term
PFM functional cusp reduction? |
|
Definition
|
|
Term
PFM non functional cusp reduction? |
|
Definition
|
|
Term
PFM buccal shoulder width? |
|
Definition
|
|
Term
PFM interproximal shoulder width? |
|
Definition
|
|
Term
PFM Lingual shoulder width? |
|
Definition
|
|
Term
PFM supragingival height of shoulder? |
|
Definition
|
|
Term
How much taper on PFM axial walls? |
|
Definition
Ideally 6 degrees but can go to 12 degrees |
|
|
Term
Width of functional cusp bevel on PFM and full metal? |
|
Definition
|
|
Term
Width of non functional cusp bevel on PFM and full metal? |
|
Definition
|
|
Term
Full metal functional cusp reduction? |
|
Definition
|
|
Term
Full metal non functional cusp reduction? |
|
Definition
|
|
Term
Full metal shoulder width? |
|
Definition
0.75-1 mm circumferentially AFTER bevel |
|
|
Term
Width of bevel on full metal shoulder? |
|
Definition
|
|
Term
Height of shoulder on full metal prep? |
|
Definition
1.5 mm supragingival but bevel puts it 0.5 mm supragingival |
|
|
Term
Bevel angle on full metal prep? |
|
Definition
45 degrees made with flame bur |
|
|
Term
What do we soak the waxed up diagnostic cast in, before taking alginate impressions? |
|
Definition
|
|
Term
Should you re-line the provisional if it is in hyperocclusion? |
|
Definition
NO this will compound your problem. Adjust occlusion THEN reline |
|
|
Term
What happens when we place an acrylic provisional in warm water to set? |
|
Definition
It speeds up setting, but causes shrinkage |
|
|
Term
When making a provisional should you put vaseline on omnivac shell? |
|
Definition
No, it will cause porosities |
|
|
Term
How long should acrylic provisionals stay on patient's teeth when you are making it initially? |
|
Definition
2 minutes...it gets hot after this! |
|
|
Term
What does it mean if your provisional snaps into place? |
|
Definition
undercut is present...fix your prep |
|
|
Term
What does it mean if margins break off on your provisional? |
|
Definition
not enough tooth structure was removed or your bevel is not angled properly |
|
|
Term
What are the dimensions and location of a pontic's contact area with the gingiva? |
|
Definition
2mm by 2mm contact area that is 1 mm buccal to crest of ridge |
|
|
Term
What are the dimensions of the connectors of a 3 unit provisional on teeth 19-21? |
|
Definition
4x4mm for molar 3x3 mm for premolar |
|
|
Term
How thick should your elastomeric impression materials be in the tray? |
|
Definition
|
|
Term
What will large bulks of impression material lead to? |
|
Definition
increased polymerization shrinkage |
|
|
Term
How far apical to the gingival margins should your baseplate wax extend when making custom trays? |
|
Definition
2 mm apical from the gingival margin |
|
|
Term
What are the dimensions of molar and incisor tissue stops on a custom tray? |
|
Definition
2x2 mm molars 2x1 mm incisors |
|
|
Term
Where do we put model releasing agent when making custom trays? |
|
Definition
NOT on the model ON the pink baseplate wax before putting on tray material |
|
|
Term
Size and angle of custom tray handle? |
|
Definition
3/4" by 3/4" and 70 degrees for mandibular |
|
|
Term
Curing times for custom trays? |
|
Definition
2 minutes on cast 1 minute off of cast paint with ABC 4 minutes tissue side up |
|
|
Term
How long should the PVS set during final impression? |
|
Definition
|
|
Term
How long should de-bubblizer stay on impression before pouring a model? |
|
Definition
60 seconds. do not rinse off |
|
|
Term
Ratio of DieKeen powder to water for pindex cast? |
|
Definition
60 g powder : 13 mL water. In preclinic this is 2 packages and 26 mL of water |
|
|
Term
Clinically what is ratio of Type IV ivory stone to water when making the pindex BASE? |
|
Definition
200 g powder to 42 mL water in vacuum mixer. |
|
|
Term
How long do we mix stone in vacuum mixer? |
|
Definition
|
|
Term
What PSI should we use in vacuum mixer? |
|
Definition
|
|
Term
For the preclinic pindex model, how far distal to the third molars should the model extend? |
|
Definition
2mm so that it fits in rubber base mold |
|
|
Term
When trimming the pindex cast, how should it converge/diverge? |
|
Definition
it should diverge toward occlusal so that it can come out of the base |
|
|
Term
What is the minimum distance Bucco-Lingually between pindex holes? |
|
Definition
|
|
Term
What is the minimum distance Mesio-Distally between pindex holes? |
|
Definition
|
|
Term
Why must the pindex holes line up bucco-lingually? |
|
Definition
to ensure a common path of draw |
|
|
Term
How long should cyanoacrylate glue dry on pindex? |
|
Definition
|
|
Term
Should the pindex pin be visible above the pink sleeve? |
|
Definition
yes, if it isn't the sleeve is upside down |
|
|
Term
What is the purpose of separator being applied to bindex cast? |
|
Definition
helps separate it from the white base |
|
|
Term
How high should the base cover the pindex cast? |
|
Definition
|
|
Term
How long should base of pindex model harden? |
|
Definition
|
|
Term
Should you use a buffalo knife to separate the pindex cast from the base? |
|
Definition
|
|
Term
How much land should surround the trimmed base of a pindex model? |
|
Definition
|
|
Term
When cutting your die off of the pindex should your cuts converge or diverge toward occlusal? |
|
Definition
diverge toward occlusal or be perfectly straight so that they can come out. She says "cuts should converge" but that is toward the apical direction |
|
|
Term
How should you hold the bur when ditching your pindex die? |
|
Definition
along axis of die NOT perpendicular to it |
|
|
Term
What is the working time of Regisil for occlusal bite record? |
|
Definition
|
|
Term
When should you remove regisil from patients mouth? |
|
Definition
|
|
Term
What happens if you don't trim your regisil accurately? |
|
Definition
|
|