Shared Flashcard Set

Details

IDEX - Ch. 5
Interior Finish Requirements
15
Art/Design
Professional
05/08/2010

Additional Art/Design Flashcards

 


 

Cards

Term
Which test is used to determine flame-spread rating and smoke developed for interior wall and ceiling finishes?
Definition

ASTM E84

Steiner Tunnel Test

Term
What class is an interior wall finish with a flame spread rating of 50 and a smoke developed rating of 300?
Definition
Class B
Term
Which test measures the extent to which non-textile finishes contribute to fire growth in a room? 
Definition

NFPA 286

Room Corner Test

 

Measures:

a. heat and smoke released

b. combustion products released

c. potential for fire spread

Term
Which test is used to classify interior floor finishes for corridors and exitways?
Definition

NFPA 253

Flooring Radiant Panel Test

 

(Note: This is used for testing carpet in CA, as per CBC)

Term
Which test is used to measure the extent to which textile finishes contribute to room fire growth?
Definition

NFPA 265

Room Corner Test for Textile Wall Coverings

Term
Which test measures the flame spread of floor coverings for all areas (not only exit areas)?
Definition
ASTM E648
Term
Which test is used for carpet flammability?
Definition

ASTM D2859

Methenamine Pill Test

 

(Note: Not referred to in CBC, but US required)

Term
Which types of flooring are not regulated by the CBC?
Definition
wood, vinyl, linoleum, terrazzo and resilient flooring not comprised of fibers
Term
What is the class rating required for trim in all occupances except Group I-3?
Definition
Class C
Term
What is the class rating for interior trim in Group I-3 occupancies?
Definition
Class B
Term
What test is used for textiles and films - normally used for window treatments?
Definition

NFPA 701

Vertical Ignition Test

Term
What are the two procedures used for NFPA 701?
Definition

Procedure 1: fabrics < 21 oz./sq. yd

Procedure 2: fabrics > 21 oz. sq. yd

Term
In which occupancy group are combustible decorative materials prohibited?
Definition
Group I-3
Term
What are 3 factors that determine the fire resistance rating required for wall and ceiling finishes?
Definition

1. Occupancy group

2. Location in building

3. Sprinkler system

Term

What are 3 different testing methods that can be used for textile wall coverings compliance?

Definition

1. ASTM E84 - Class A and automatic sprinkler system

2. NFPA 265 - Method B

3. NFPA 286

 

Supporting users have an ad free experience!