Building Planning
6
Other
Professional
08/29/2007

Additional Other Flashcards

 


 

Cards

Term
Section R319
Protection Against Decay

REQUIRED TO BE AWPA U1 TREATED

Wood joists or the bottom of a wood structural floor when closer than ___ inches or wood girders closer than ___ inches to the exposed ground
Definition
18 and 12 Inches
Term
Section R310
Escape and Rescue Openings

All emergency escape and rescue openings shall have a minimum net clear opening of ____ sqr feet

Grade floor openings shall have a net opening of ____ sqr feet
Definition
5.7

5.0
Term
Section R319
Protection Against Decay

REQUIRED TO BE AWPA U1 TREATED



The ends of wood girders entering exterior masonry or concrete walls having clearances of less than ___ inch on top sides and ends
Definition
½ inch
0.5
Term
Section R310
Escape and Rescue Openings

Minimum opening height shall be __

Minimum opening width shall be ___
Definition
24 inches

20 inches
Term
R308.4 Hazarous Locations

Glazing in an individual fixed or openable panel adjacent to a door where the nearest verticle edge is a __ inch arch of the door closed and bottom edge less than ___ inches above the floor
Definition
24 inches

60 inches
Term
R308.4 Hazarous Locations

Glazing in an individual fixed or openable panel that meets all of the following:

Exposed area larger than __ sqr ft

Bottom edge less than __ inches above the floor

Top Edge more than __ inches above the floor

One
Definition
Exposed area larger than _9_ sqr ft

Bottom edge less than _18_ inches above the floor

Top Edge more than _36_ inches above the floor

One or more walking surface within _36_ inches horizontally
Supporting users have an ad free experience!