Term
True or False: The needle must remain sterile at all times? |
|
Definition
|
|
Term
What parts of a syringe must remain sterile at all times? |
|
Definition
Tip and Inner Core Plunger |
|
|
Term
|
Definition
Tip Barrel Inner Core Plunger |
|
|
Term
|
Definition
|
|
Term
|
Definition
The larger the Gauge the smaller the opening. |
|
|
Term
|
Definition
Ampules and Syringes Vials that do not contain preservatives |
|
|
Term
|
Definition
Aerosol cans and vials that contain preservatives |
|
|
Term
|
Definition
Used to puncture the rubber diaphragm located inside the administration set. |
|
|
Term
True or False: The cover protecting the intravenous administration set spike should not be removed outside the hood prior to inserting it into the IV bag administration set port because it must remain sterile at all times. |
|
Definition
|
|
Term
|
Definition
Is part of the intravenous administration set which is used to calculate the rate at which the solution is being infused. |
|
|
Term
|
Definition
Used to regulate the rate of infusion |
|
|
Term
|
Definition
Used to add medication to the administration set which will be pushed into the vein. |
|
|
Term
|
Definition
is used to connect the administration set to the catheter. |
|
|
Term
|
Definition
Is used to prevent the introduction of particulate matter. The device must be no greater than 5 micron in size to prevent the transfer of particulate matter. |
|
|
Term
What medication should not be filtered? |
|
Definition
|
|
Term
|
Definition
Room air is pulled into the hood. Dust, lint, and other large contaminants are removed here. |
|
|
Term
The prefilter should be checked and either cleaned or changed at least on a ______ basis. |
|
Definition
|
|
Term
|
Definition
this filter removes particulates and microorganisms from the air that are 0.3 microns and larger, but does not remove vapors or gases. |
|
|
Term
The HEPA filter is located at the back of the hood facing the preparer in the ______ airflow hood. |
|
Definition
|
|
Term
The HEPA filter must be checked every ____ months or when the hood is relocated |
|
Definition
|
|
Term
|
Definition
iis the clean zone where all sterile compounding manipulations should be performed. |
|
|
Term
How many inches inside the laminar airflow hood should you be? |
|
Definition
|
|
Term
The USP/NF 797 states that when carts are being used they ____________clean zones unless they are cleaned and sanitized before returning to the clean room. |
|
Definition
|
|
Term
How many minutes should the hood be allowed to run prior to use? |
|
Definition
|
|
Term
If the blower is turned off, how many people can enter the buffer area for the purposes of turning on the blower (for a minimum of 30 minutes) and of sanitizing the work surfaces? |
|
Definition
|
|