Term
What are the Five Areas of recommended control measures under SMACNA "IAQ Guidelines for Occupied Buildings Under Construction"? |
|
Definition
1. HVAC Protection 2.Source Control 3. Pathway Interruption 4. Housekeeping 5. Scheduling |
|
|
Term
What type of testing does the Carpet & Rug Institute use for its certifications? |
|
Definition
|
|
Term
What is the Reference Standard for EQ P1 Minimum IAQ PErformance? |
|
Definition
ASHRAE 62.1-2004 Ventilation for Acceptable IAQ |
|
|
Term
What is the Reference Standard for EQ P2 Environmental Tobacco Smoke? |
|
Definition
ANSI/ASTM-E779-03 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization AND Residential Manual for Compliance with California's 2001 Energy Efficiency Standards (For Low Rise Res. Bldgs), Chapter 4 |
|
|
Term
What are the reference standards for EQ C2 Increased Ventilation? |
|
Definition
Mechanically Ventilated: ASHRAE 62.1-2004 (exceed by 30%) Natural Ventilation: Carbon Trust Good Practice Guide 237 (1998) AND CIBSE Applications Manual (to determine if natural ventilation is effective by following the diagrams) |
|
|
Term
What are the reference standards for EQ C3.1 Const. IAQ Management Plan (During Construction)? |
|
Definition
SMACNA: IAQ Guidelines for Occupied Buildings Under Construction ANSI/ASHRAE 52.2-1999: Method for testing air cleaning devices for removal efficiency (Air Filters) |
|
|
Term
What is the reference standard for EQ C3.2 Const. IAQ Management - (Before Occupancy)? |
|
Definition
US EPA: Compendium of Methods for the Determination of Air Pollutants in Indoor Air (For IAQ Testing in Option 2) |
|
|
Term
What is the reference standard for EQ C4.1 Low-Emitting Materials Adhesives and Sealants |
|
Definition
SCAQMD Rule # 1168 for adhesives, sealants, and sealant primers. Green Seal Standard for Commercial Adhesives GS-36 for Aerosol Adhesives |
|
|
Term
What are the reference standards for EQ C4.2 Low-Emitting Materials Paints and Coatings? |
|
Definition
Green Seal Standard GS-11 for Interior Non-Flat Paints Green Seal Standard GC-03 for Anti-Corrosive / Rust Paints SCAQMD Rule 1113 for Architectural Coatings (Clear Wood Finishes, Floor Coatings, stains, sealers, shellacs) |
|
|
Term
What is the reference standard for EQ C4.3 Low-Emitting Materials Carpet Systems? |
|
Definition
Carpet & Rug Institute (CRI) Green Label Plus Testing Program |
|
|
Term
What is the reference standard for EQ C5 Indoor Chemical & Pollutant Source Control? |
|
Definition
ANSI/ASHRAE 52.2-1999 Method of testing general ventilation air cleaning devices for efficiency removing different particle sizes (Air Filters) |
|
|
Term
What are the reference standards for EQ C6.2 Controllability of Systems- Thermal Comfort? |
|
Definition
ANSI/ASHRAE 62.1-2004 (Ventilation) AND ANSI/ASHRAE 55-2004 Thermal Environmental Conditions for human Occupancy |
|
|
Term
What is the reference standard for EQ C7.1 Thermal Comfort - Design |
|
Definition
ANSI/ASHRAE 55-2004 Thermal Environmental Conditions for human Occupancy |
|
|
Term
What is the reference standard for EQ C7.1 Thermal Comfort - Verification |
|
Definition
ANSI/ASHRAE 55-2004 Thermal Environmental Conditions for human Occupancy |
|
|
Term
What is the reference standard for SS P1 Const. Activity Pollution Prevention? |
|
Definition
Storm Water Management for Construction Activities (USEPA Document No EPA...) Chapter 3 |
|
|
Term
What is the reference standard for SS C1 Site Selection? |
|
Definition
United Code of Federal Regulations (CFR) Definition of Agricultural Land FEMA - 100 year Flood Definition Endangered Species List Code of Federal Regulations - Definition of Wetlands |
|
|
Term
What is the reference standard for SS C3 Brownfield Redevelopment? |
|
Definition
ASTM E1903-97 Phase II Environmental Site Assessment EPA - Brownfield Definition |
|
|
Term
What is the reference standard for SS C4.4 Parking Capacity? |
|
Definition
If there is No Zoning Requirement: A) Meet req. of Portland, Oregon, Zoning Code: Title 33, Chapter 33.266 (Parking & Loading) OR B) Install 25% less parking than the building type's average listed in the Institute of Transportation Engineers' Parking Generation Study, 3rd Edition |
|
|
Term
What are the reference standards for the definitions of Low-Emission & Fuel-Efficient Vehicles in SS C4.3? |
|
Definition
Low-e and Fuel efficient vehicles are defined as vehicles that are either classified as Zero Emission Vehicles (ZEV) by the Cal. Air Resources Board OR have achieved a minimum green score of 40 on the American Council for an Energy Efficient Economy (ACEEE) annual vehicle rating guide |
|
|
Term
What is the reference standard for SS C6.2 Stormwater Design - Quality Control? |
|
Definition
Guidance Specifying Management Measures for Sources of Non-Point Pollution in Coastal Waters, January 1993 (EPA Doc.) |
|
|
Term
What is the reference standard for SS C7.2 Heat Island Effect - Roof? |
|
Definition
ASTM E1980-01 ASTM E408-71 ASTM E903-96 ASTM 1918-97 ASTM C1371-04 ASTM C1549-04 |
|
|
Term
What is the reference standard for SS C8 Light Pollution Reduction? |
|
Definition
ASHRAE/IESNA Standard 90.1-2004 Energy Standard for bldgs. except low-rise Residential - Lighting, section 9 (without amendments) |
|
|
Term
What is the reference standard for WE C3.1 and 3.2 Water Use Reduction 20% and 30%? |
|
Definition
Energy Policy Act (EPAct) of 1992 sets requirements for fixture flow rates water closets (1.6 gpf) Urinals (1.0 gpf) Showerheads, faucets, and aerators (2.5 gpm) Metering faucets (0.25 gal/cy) (showerheads, faucets and aerators use 80 psi) |
|
|
Term
What is the reference standard for EA P2 Minimum Energy Performance? |
|
Definition
ASHRAE/IESNA 90.1-2004 Mandatory Provisions AND Prescriptive Requirements or Performance Requirements |
|
|
Term
What are the reference standards for EA C1 Optimize Energy Performance? |
|
Definition
Opt. 1: ASHRAE/IESNA 90.1-2004 (Appendix G) Opt. 2: ASHRAE Advance Energy Design Guide for Small Office Bldgs. 2004 (under 20,000 sf) Opt.3: Adv. Bldgs. Core Performance Program (Under 100,000 sf) Opt. 4: Adv. Bldgs. Benchmark Version 1.1 (No longer available for newly registered projects) |
|
|
Term
What is the reference standard for EA C2 On-Site Renewable Energy? |
|
Definition
ASHRAE/IESNA 90.1-2004 EA C2 uses building annual energy cost calculated from EA C1 OR can use DOE Commercial Buildings Energy Consumption Survey (CBECS) database for estimated electricity use by building type. |
|
|
Term
What Protocol is mentioned in EA C4 Enhanced Refrigerant Management? |
|
Definition
Intent: Reduce Ozone Depletion and support early compliance with the Montreal Protocol while minimizing direct contributions to global warming. |
|
|
Term
What is the reference standard for EA C5 Measurement & Verification? |
|
Definition
International Performance Measurement & Verification Protocol (IPMVP) Vol. III: Concepts and Options for determining Energy Savinds in New Construction, April, 2003 (Option D - Whole Building Calibration Simulation or Option B - Energy Conservation Measure Isolation (ECM Isolation)) |
|
|
Term
What is the reference standard for EA C6 Green Power? |
|
Definition
Renewable sources are as defined by the Center for Resource Solutions (CRS) Green-e products certification requirements. *power product does not have to be Green-e certified, but must meet the program's technical requirements. (RECs, Tradable RECs, green tags, and other forms of green power are eligible) |
|
|
Term
What is the reference standard for MR C4.1 and 4.2? |
|
Definition
International Standard ISO 14021 is used to define recycled content (post and pre-consumer). |
|
|
Term
What is the reference standard for MR C7 Certified Wood? |
|
Definition
Forest Stewardship Council's (FSC) Principles and Criteria |
|
|