Term
|
Definition
Max Takeoff: 64.5 psi
Max Continuous: 56.0 psi
Transient (at 104% N2):
-72.0 psi for 10 seconds
-80.0 psi for 3 seconds |
|
|
Term
Turbine Outlet Temperature (TOT) Limits |
|
Definition
Maximum takeoff: 793 C
Maximum continuous: 737 C
Maximum for start: 150 C
Transient limits:
Start and shutdown: 793 C to 927 C for up to 10 seconds, with a peak at 927 C for no more than 1 second
During flight: 793 C-843 C <= 6 seconds |
|
|
Term
Gas Producer (N1) Limits
(Max. continuous, idle, transient) |
|
Definition
Maximum Continuous: 104%
Idle: 61-65%
Transient:
104-106% for 15 seconds |
|
|
Term
Power Turbine (N2) speed limits
(Normal power and transient overspeed limits) |
|
Definition
Normal power on operations: 103% to 104%