Shared Flashcard Set

Details

Main Turbine Auxiliaries (Turb Aux)
BWR Systems
16
Other
Not Applicable
07/05/2012

Additional Other Flashcards

 


 

Cards

Term
Turb Aux

Describe turbine steam seal system.
Definition
-Above 50% leak off from HP turbine seals and steam admission valves provides pressure at 4 psig.
-Less than 50% 4 psig maintained by regulator at 4 psig (off bypass line).
-Less than 150psig bypass valve used.
-Exhauster maintains 10"Hg.
-Exhauster condenser cooled by feedwater from cond pump.
Term
Turb Aux

Describe the power supplies for the exhaust blowers.
Definition
-11 from MCC-131.
-12 from MCC-121.
Term
Turb Aux

Describe the power supply to the Aux oil pump.
Definition
15 bus.
Term
Turb Aux

Describe the power supply to DC emergency bearing oil pump.
Definition
17 battery.
Term
Turb Aux

Describe the power supply to the turning gear oil pump.
Definition
MCC-142A.
Term
Turb Aux

Describe the lift pumps.
Definition
-6 pumps supply oil at 500# to bearings 3-8 to lift shaft.
-Auto start at 5psig supply pressure.
-Manually secure at >900rpm (oil wedge created).
-Low pressure alarm at 440psig.
Term
Turb Aux

Describe normal lube oil temps.
Definition
-Normally 110-112F.
-On turning gear 80-90F.
-Rise across bearings should not exceed 50F.
Term
Turb Aux

Describe cooling to lube oil cooler.
Definition
Service water.
Term
Turb Aux

Describe the Aux oil pump.
Definition
-Primarily used during startup and shutdown.
-Supplies oil at 180psig.
-Will auto start if pressure drops below 201#.
Term
Turb Aux

Describe the main shaft oil pump.
Definition
-Driven by turbine by helix gears.
-Operates sufficiently at 1600rpm.
Term
Turb Aux

Describe the booster oil pump.
Definition
-Oil driven pump.
-Supplies NPSH to main shaft oil pump.
-Operates at >1600 turbine rpm.
Term
Turb Aux

Describe the turning gear oil pump.
Definition
-Auto starts when mail oil pressure drops below 136psig.
Term
Turb Aux

Describe the emergency bearing oil pump.
Definition
Auto starts when header pressure falls to 21psig.
Term
Turb Aux

Describe the turning gear.
Definition
-Once engaged can only be disengaged by driving turbine with steam.
-Motor must be moving to engage for meshing.
Term
Turb Aux

Describe when the turning gear motor starts.
Definition
-Oil bressure to bearings is > than 15psi.
-Turbine speed is less than .6rpm.
-Main transfer output breakers 8N7 and 8N8 are open.
-Turning gear is not already engaged.
-Turning gear handswitch in AUTO.
Term
Turb Aux

Describe when the turning gear will auto engage.
Definition
-Turbine speed is less than .6rpm.
-All 3 ligt pump motors are running.
-Turning gear motor is running.
Supporting users have an ad free experience!