Term
NFPA 701, Standard Methods of Fire Tests for Flame-Resistant Textiles and Films (aka Vertical Ignition Test) UL 214, Test for Flame Propogation of Fabrics and Films |
|
Definition
Defines two testing procedures to assess the propagation of flame beyond the original flame source for drapery or other vertcicallhy installed fabrics |
|
|
Term
NFPA 260, Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture CAL TB 117, ASTM E1353 |
|
Definition
Tests the resistance of upholstered furniture components, seperately, to flame and cigarette ignition |
|
|
Term
NFPA 261, Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Mock-Up Upholstered Furniture Assemblies CAL TB 116, BIFMA X5.7 |
|
Definition
Tests the resistance of upholstered furniture composites/mock-ups for flame and cigarette ignition |
|
|
Term
NFPA 266, Standard Method of Test for Fire Characteristics of Upholstered Furniture Exposed ot Flaming Ignition Source CAL TB 133 |
|
Definition
One of the strictest tests that evaluates the effect of an open flame on an actual sample of a chair |
|
|
Term
|
Definition
Abrasion resistance test that results in double-rubs |
|
|
Term
|
Definition
Abrasion test where fabric is tested on a on a platform by exposing it to two revolving abrasive wheels |
|
|
Term
NFPA 80, Standard for Fire Doors and Windows ASTM E 163 |
|
Definition
Test that deals with the construction and installation of fire doors |
|
|
Term
NFPA 252, Standard Methods for Fire Tests of Door Assemblies UL 10B |
|
Definition
Standard method for testing fire door assemblies |
|
|
Term
|
Definition
Standard for the installation and spacing of sprinkler systems |
|
|
Term
ASTM E 119 UL 263, Fire Tests for Building Construction and Materials |
|
Definition
Standard method of of fire tests of building construction and materials, involves building a sample of the wall or floor/ceiling assembly |
|
|
Term
ASTM E 84 Steiner Tunnel Test |
|
Definition
Standard test method for surface burning characteristics of building materials, where a sample is placed in a tunnel test chamber, measures flame spread |
|
|
Term
ASTM E 648 NFPA 253 Flooring Radiant Panel Test |
|
Definition
Tests a sample of carpet in the horizontal position and measures the flame spread |
|
|
Term
ASTM D 2859 Methenamine Pill Test |
|
Definition
Required test for all carpet in the United States |
|
|
Term
ASTM E 662 NFPA 258 Smoke Density Chamber Test |
|
Definition
Measures the smoke developed from both flaming and nonflaming solid materials |
|
|
Term
ICC/ANSI A117.1-1998, Accessible and Useable Buildings and Facilities |
|
Definition
Standards for accessibility |
|
|