Shared Flashcard Set

Details

Phenom 300E1 Oxygen Sys Question Bank
Systems questions
5
Aviation
Professional
07/20/2023

Additional Aviation Flashcards

 


 

Cards

Term
What are the three positions of the oxygen supply control knob and their
functions?
Definition
CREW ONLY: disables automatic deployment of passenger oxygen masks.
PAX AUTO: enables automatic deployment of passenger oxygen masks
when cabin pressure altitude is above 14700 ft (+300/-300 ft), if the OXYGEN
SUPPLY handle is pushed.
PAX OVRD: deploys the passenger oxygen masks regardless of
cabin altitude, if the OXYGEN SUPPLY handle is pushed.
Term
What is the purpose of the Auto Dilution Valve?
Definition
When pulled, the flight crew will breathe cabin air, when oxygen supply is not
required. When pushed, the flight crew will breathe oxygen according to the
position of the regulator knob.
Term
When will the valve automatically close?
Definition
In case of cabin decompression. Also, the ADV is capable of closing automatically
even without cabin decompression. (Normally, cabin pressure
altitudes from 8300 to 10000 ft cause the valve to close).
Term
When do the passenger oxygen masks automatically deploy?
Definition
14700 ft (+300/-300 ft).
Term
What does a “CAB ALTITUDE HI” CAS message indicate?
Definition
Cabin altitude is 10,000 ft or higher.
Supporting users have an ad free experience!