Term
|
Definition
A heavy stream appliance that is designed to provide a fire stream from above ground level |
|
|
Term
How are ladder pipes operated? |
|
Definition
Directly by a firefighter @ the top of the aerial ladder or by using guidelines from the ground |
|
|
Term
What equipment makes up a ladder pipe? |
|
Definition
appliance smooth bore tips 500GPM spray tip 100' of 3"hose w/ 2 1/2" couplings 2 1/2" shut off 4" to 2 1/2" reducer 4" double male hose straps |
|
|
Term
Which member is responsible for the placement and/or spotting of the aerial ladder? |
|
Definition
|
|
Term
How far from a ladder pipe operation will an engine spot? |
|
Definition
100' from the cluster @ the base of the aerial ladder |
|
|
Term
Who attaches the ladder pipe to the aerial ladder? |
|
Definition
|
|
Term
How is the ladder pipe attached to the aerial ladder? |
|
Definition
locked and strapped with one strap on each end of the appliance |
|
|
Term
What nozzles are used on a ladder pipe? |
|
Definition
Seagrave apparatus uses 600GPM straight tip and the 500GPM fog nozzle
LTI apparatus uses 800GPM (1 3/4) 750GPM turbo master |
|
|
Term
How is a ladder pipe converted into an improvised standpipe? |
|
Definition
By placing an aerial ladder with ladder pipe attached into an above ground window |
|
|
Term
If a person is at the top of an aerial ladder during a ladder pipe operation, what should that person not wear? |
|
Definition
|
|
Term
What should be removed from the ladder pipe when using the fog nozzle with a member on the end of the aerial ladder? |
|
Definition
|
|
Term
How many sides should the member at the top of the aerial ladder buckle into during ladder pipe operations? |
|
Definition
|
|
Term
What size safety line(s) are required if a member is on the ladder operating the ladder pipe? |
|
Definition
|
|
Term
What are foam eductors used in conjunction with? |
|
Definition
5 gallon containers of AFFF (light water) and ATC (alcohol type concentrate) |
|
|
Term
|
Definition
synthetic foam forming liquid used at a ratio of 6 parts concentrate to 94 parts water (fresh or sea) |
|
|
Term
How many more times effective is light water on open surface gasoline fires than protein type foams? |
|
Definition
more than 3 times as effective |
|
|
Term
AFFF should not be used on what type of incidents? |
|
Definition
Polar solvents (acetone, methyl ethyl ketone) |
|
|
Term
How do wet water proportioners work? |
|
Definition
By automatically metering a wetting agent into the fire stream |
|
|
Term
The wet water proportioner is primarily used on... |
|
Definition
overhaul, especially on shingles, baled goods, and most class A combustibles |
|
|
Term
What should be done after using a wet water proportioner? |
|
Definition
Flush all lines with fresh water |
|
|
Term
What do you normally attach a wet water anti-siphon sprayer to? |
|
Definition
|
|
Term
How are distributors normally operated? |
|
Definition
Through holes cut into floors, roofs, docks, etc |
|
|
Term
How many PSI are normally supplied to the wet water anti-siphon sprayer? |
|
Definition
|
|
Term
The 2 1/2" bresnan distributor is equivalent to what size hose line? |
|
Definition
|
|
Term
How many GPM does a bresnan distributor put out? |
|
Definition
|
|
Term
What are siphon ejectors used for? |
|
Definition
De-watering operations or firefighting operations |
|
|
Term
Siphon ejector efficiency is mostly regulated by what? |
|
Definition
Pressure in the supply line |
|
|
Term
What size siphon ejectors does LAFD use? |
|
Definition
|
|
Term
The adjustment wheel on the 2 1/2" siphon ejector should be set where? |
|
Definition
Midway of the scale for pressure of 40 to 60PSI |
|
|
Term
Portable monitors are similar in manner to what other appliances? |
|
Definition
Wagon batteries and ladder pipes |
|
|
Term
What sized tips are provided with portable monitors? |
|
Definition
|
|
Term
Where would you find diffusing vanes? |
|
Definition
In the tips of appliances without a barrel |
|
|
Term
What are the horizontal rotation limits of a portable monitor? |
|
Definition
|
|
Term
How is control of the vertical plane achieved? |
|
Definition
|
|
Term
Where are wagon batteries located? |
|
Definition
Permanently mounted on pumping apparatus |
|
|
Term
Where should apparatus be spotted for use of wagon batteries on upper floors? |
|
Definition
Far enough away to permit the stream to enter the building at a 30 degree angle |
|
|
Term
Effectiveness of the wagon battery on upper floors is limited to what height? |
|
Definition
|
|
Term
Approx. what % of the FD's calls involve auto fires? |
|
Definition
|
|
Term
What is the # 1 priority during emergency operations? |
|
Definition
|
|
Term
How should apparatus be spotted at automobile fires? |
|
Definition
|
|
Term
List some additional resources if water supply is inadequate on car fires. |
|
Definition
Additional apparatus requests hydrants swimming pools/reservoirs water tank trucks aerial ladder for improvised standpipe |
|
|
Term
Which battery cable should be disconnected first during auto fires? |
|
Definition
|
|
Term
What causes an explosion hazard in vehicle batteries? |
|
Definition
|
|
Term
What hazards are associated with auto air conditioners? |
|
Definition
Freon gas is under pressure May emit toxic gases phosgene and fluoride if heated to decomposition |
|
|
Term
What is the leading cause of engine compartment fires? |
|
Definition
Fuel related problems
Fuel line rupture with fuel pump still pumping fuel
Fuel coming into contact with various ignition sources |
|
|
Term
How are electrical fires in passenger area handled? |
|
Definition
Disconnect electrical power and treat as class A fire |
|
|
Term
List the hazards associated with upholstery in car fires |
|
Definition
Contributes to fire spread Produces toxic smoke Provides abundant fire load Requires extensive overhaul |
|
|
Term
What hazards are associated with fires in the trunk space? |
|
Definition
Trunk/hatch hold open devices may use springs, inert gas piston cylinders that can fail when heated.
Contents in storage areas may involve toxic, flammable, corrosive, or other hazardous materials |
|
|
Term
What are the features of a hydraulic energy absorbing bumper? |
|
Definition
Bumper can travel up to 3" Gas chamber filled with inert, non flammable gases (nitrogen and helium) pressurized to 150psi Above chambers separated by floating piston |
|
|
Term
What are the features of a mechanical energy bumper? |
|
Definition
Bumper can travel up to 4" Heavy spring used to absorb impact |
|
|
Term
What tool should not be used when working adjacent to car bumpers? |
|
Definition
|
|
Term
Where is safety glass located on an automobile? |
|
Definition
|
|
Term
Removing a gas cap at a car fire can present what hazard? |
|
Definition
|
|
Term
What are some features of gasoline? |
|
Definition
Flash point: -45 degrees F Specific gravity: 0.8 Water soluble: No |
|
|
Term
What are some features of diesel # 2? |
|
Definition
Flash point: 125 degrees F Specific gravity: less that 1.0 Water soluble: No |
|
|
Term
What should be considered when mitigating fuel leaks? |
|
Definition
Spotting of apparatus (uphill and upwind) Positioning of equipment Eliminating ignition sources Determining location of leak Containment Absorption Dilution |
|
|
Term
What is the minimum deployment at any auto fire? |
|
Definition
1 1/2" line and dry chemical extinguisher |
|
|
Term
Where should the dry chemical extinguisher be positioned during car fires? |
|
Definition
The windward side for personnel protection |
|
|
Term
|
Definition
Explosion resulting from the introduction of oxygen into a confined space that is both pressurized with heated flammable gases and deficient in oxygen |
|
|
Term
|
Definition
Sudden ignition of combustible gases and/or surfaces in an involved area resulting in a sudden and intense rise in temperature. |
|
|
Term
What does BLEVE stand for? |
|
Definition
Boiling liquid expanding vapor explosion |
|
|
Term
What are some properties for liquified petroleum gas (LPG) |
|
Definition
Heavier than air Settles in low lying and confined areas Visible vapor cloud, but can't accurately define flammable area parameters Vapors can flashover the entire confined area if ignited Vapor clouds can be dispersed with a fog stream |
|
|
Term
What is a hazard associated with the plastic used in vehicles? |
|
Definition
The production of toxic gases |
|
|
Term
What are some hazards with combustible metals during car fires? |
|
Definition
Magnesium combines readily with oxygen |
|
|
Term
What can water decompose into that will add to the intensity of the fire? |
|
Definition
Oxygen and hydrogen (The released hydrogen adds to the fire's intensity) |
|
|
Term
CHP has determined that the excessive use of warning lights causes...., especially in drunk drivers |
|
Definition
|
|
Term
The vapor canister in vehicles in usually located where? |
|
Definition
The lower, forward portion of the engine compartment
Can also be located in one of the front wheel wells |
|
|
Term
What are the main causes of tire fires? |
|
Definition
Overheated brakes or under-inflation |
|
|
Term
What is a problem with tinted windows? |
|
Definition
They can camouflage smoke filled vehicles |
|
|
Term
Most casulaties (loss of life or property) occur from fires following what type of collisions? |
|
Definition
|
|
Term
What is a tool that can be used to prevent unexpected vehicle movement? |
|
Definition
|
|
Term
What is the effective range for a 20lb dry chem extinguisher? |
|
Definition
|
|
Term
How can backdrafts be avoided in car fires? |
|
Definition
Cross ventilation (break out the windows) |
|
|
Term
How can the flow of LPG through piping be controlled? |
|
Definition
Close the valves found on the storage cylinder |
|
|
Term
According to training bulletin 21 (ladder pipe operation), at what degree should the truck be jackknifed from in-line and away from the direction of the ladder extension? |
|
Definition
|
|
Term
How should the hose be laid on the ladder during ladder pipe operations? |
|
Definition
On the rungs centered between the beams |
|
|
Term
What is the limit on nozzle tip size for ladder pipe operations? |
|
Definition
|
|
Term
What size hose does LAFD use on ladder pipe operations? |
|
Definition
3" hose with 2 1/2" couplings |
|
|
Term
What is the maximum climbing angle that a 100' aerial ladder should be at for ladder pipe operations? |
|
Definition
|
|
Term
If a 100' aerial ladder is extended to at least 80', what is the minimum climbing angle? |
|
Definition
|
|
Term
Because ladder pipe operations require such high pressures, where should shut down ideally take place? |
|
Definition
At the pump on the hydrant |
|
|
Term
At what angle should the ladder obtain before the hose line is loaded? |
|
Definition
|
|
Term
What is the maximum amount of firefighters allowed at the top section of the ladder during ladder pipe ops? |
|
Definition
|
|
Term
At what PSI are solid master stream operated? |
|
Definition
|
|
Term
At what PSI are spray master streams operated |
|
Definition
|
|
Term
What is the typical flow range for master streams? |
|
Definition
|
|