Term
|
Definition
A minut (tiny) bubble of pure energy that has no weight or mass |
|
|
Term
|
Definition
A measure of how well the radiograph reproduces the fine details or outlines of an object |
|
|
Term
|
Definition
effects of radiation that cause illness and are responsible for poor health such as cancer, leukemia and cataracts but are not passed to offspring |
|
|
Term
|
Definition
a focal spot in the anode |
|
|
Term
|
Definition
|
|
Term
|
Definition
positive electrode in the xray tube |
|
|
Term
|
Definition
concept of radiation protection that states all exposure should be kept " as low as possible. |
|
|
Term
|
Definition
high energy ionizing electromagnetic radiation |
|
|
Term
|
Definition
the blurred or indistinct area that surrounds an image |
|
|
Term
|
Definition
the negative electrode in the xray tube |
|
|
Term
|
Definition
one one thousandth (1/1,000) of an amprere a unit of measurement used to describe teh intensity of an electrical current |
|
|
Term
|
Definition
anything that occupies space and has form or shape |
|
|
Term
Components of a control panel |
|
Definition
Master swithc indicator light, selector buttons, exposure buttons |
|
|
Term
|
Definition
the proportional enlargement of a radiographic image |
|
|
Term
|
Definition
device used to protect the reproductive and blood forming tissues from scatter radiation |
|
|
Term
|
Definition
tiem between exposure to ionizing radiation and the apperance of symptoms |
|
|
Term
|
Definition
highest voltage of radiograph tube used during radiograph exposure |
|
|
Term
|
Definition
Radiation that produces ionization resulting in harmful effects |
|
|
Term
|
Definition
process by which electrons are removed from atoms causing the harmful effects of radiation in humans |
|
|
Term
|
Definition
An electrally charged particle |
|
|
Term
|
Definition
Effects of radiation that are passed on to future generations through genetic cells |
|
|
Term
|
Definition
Flexible arm that is attached to the xray tubehead |
|
|
Term
|
Definition
|
|
Term
|
Definition
negatively charged particle in the atom |
|
|
Term
|
Definition
the amount of energy absorbed by the tissues |
|
|
Term
|
Definition
change in size of an image on a radiograph caused by incorrect vertical angulation |
|
|
Term
|
Definition
process of making radiographs of the teeth and adjacent structures by exposure to radiographs |
|
|
Term
|
Definition
the overall darkness or blackness of a radiograph |
|
|
Term
|
Definition
the differences in degrees of blackness on a radiograph |
|
|
Term
|
Definition
device that automates all film processing steps |
|
|
Term
|
Definition
assists in teh positioning of the PID |
|
|
Term
|
Definition
Radiographic view that shows the crowns of both arches on one film |
|
|
Term
|
Definition
|
|
Term
|
Definition
Holder for extraoral films during exposure |
|
|
Term
|
Definition
Shows the bony and soft tissues areas of the facial profile |
|
|
Term
|
Definition
Film designed for use in film duplicating machines |
|
|
Term
|
Definition
A layer on the xray film that contains the radiograph sensitive crystals |
|
|
Term
|
Definition
Film designed for use in film duplicating machines |
|
|
Term
|
Definition
Device used to position and hold dental xray films |
|
|
Term
|
Definition
the sensitivity of the emulsion on the film to radiation |
|
|
Term
|
Definition
Device used to convert xray energy into visible light, which in turn exposes screen film |
|
|
Term
|
Definition
Film designed for placement in the patients mouth |
|
|
Term
|
Definition
Colored side of the film that faces the tounge |
|
|
Term
|
Definition
The invisible image on the xray film after exposure but before processing |
|
|
Term
|
Definition
Radiographic view that shows lrge areas of the maxilla or mandible |
|
|
Term
|
Definition
provides a wide view of the upper and lower jaws |
|
|
Term
|
Definition
radiographic view that shows the crown, root tip, and surrounding structures |
|
|
Term
|
Definition
A series of steps that changes the exposed film intoa radiograph the steps include developing rinsing fixing washing and drying |
|
|
Term
|
Definition
Image produced on aphotosensitive film by exposing the film to radiation then processing it |
|
|
Term
|
Definition
solid-white side of the film that faces the xray tube |
|
|
Term
|
Definition
an image on a radiograph that is not an actual struture but is caused by the technique |
|
|
Term
|
Definition
process of informing the patient about the procedure; for example the procedure for taking xrays |
|
|
Term
|
Definition
permission granted by a patient after being informed about the details of a procedures |
|
|
Term
|
Definition
accountable or legally responsible |
|
|
Term
|
Definition
a plan to nesure that the dental office produces consistent high quality images with a aminimum of exposure to patients and personnel |
|
|
Term
|
Definition
device constructed of layered aluminum steps to demonstrate the film densities and contrasts |
|
|
Term
|
Definition
an illuminated boxlike device useed to veiw radiographs |
|
|
Term
|
Definition
alignment of central ray of xray beam in horizontal and vertical planes |
|
|
Term
|
Definition
intraoral technique of exposing periapical films |
|
|
Term
|
Definition
|
|
Term
|
Definition
type of radiograph used in the interproximal examination |
|
|
Term
|
Definition
area of the mesial or distal surfaces of a tooth that touches adjacent tooth in the same arch |
|
|
Term
|
Definition
imaginary line dividing the tooth longitudinally (vertical) into two equal halves |
|
|
Term
|
Definition
used to examine large areas of the upper or lower jaw |
|
|
Term
|
Definition
used to examine large areas of the upper or lower jaws |
|
|
Term
|
Definition
moving or lying in the same plane always seperated by the same distance |
|
|
Term
|
Definition
intersecting at or forming a right angle |
|
|
Term
|
Definition
impairment in certain fucntions of the body, such as hearing vision, or mobility |
|
|
Term
|
Definition
angle of 90 degrees formed by two lines perpendicular to each other |
|
|
Term
|
Definition
special device that allows the operator to easily position both film and the patient |
|
|
Term
charge coupled device(ccd) |
|
Definition
image receptor found int eh intraoral sensor |
|
|
Term
|
Definition
filmless imaging system that uses a sensor to capture images, tehn converts the images into electronic pieces and stores them in a computer |
|
|
Term
|
Definition
to convert an image into a digital form taht in turn can be processesed by a computer |
|
|
Term
|
Definition
feature that allows the operator to adjust the miliamerage and kilovoltage settings |
|
|
Term
|
Definition
imaginary three dimensional horseshoe shaped zone used to focus panoramic radiographs |
|
|
Term
|
Definition
imaginary plane that passes through the top of the ear canal and the bottom of the eye socket |
|
|
Term
|
Definition
device used to reduce the amount of scatter radiation that reaches extraoral film |
|
|
Term
|
Definition
imaginary line that divides the patients face into right and left sides |
|
|
Term
|
Definition
small detector that is placed intraorally to capture a radiographic image |
|
|
Term
|
Definition
joint on each side of the head that allows for movement of the mandible |
|
|
Term
|
Definition
radiographic technique that allows imaging of one layer or section of the body while blurring images from structures in other planes |
|
|