Shared Flashcard Set

Details

SH-60B Emergency Procedures
N/A
19
Aviation
Not Applicable
09/08/2011

Additional Aviation Flashcards

 


 

Cards

Term

Immediate Landing/Ditching

Definition
  • Harness, Locked
  • Seat, up and aft
  • Windows, jettison as required
  • ASO table, up and locked
  • Assume crash position
Term

Underwater Egress

Definition
  • HABD, as required
  • Cord(s), disconnect
  • Door/window, open/jettison
  • Place hand on known reference point
  • Harness, release
  • Exit helicopter

After Egress:

  • Swim clear of helicopter and inflate LPU

 

 

 

Term

Cockpit Fire/Cabin Fire

Definition

If source is known:

  • Affected power switches and CBs
    • Secure
  • Portable Fire Extinguisher
    • As Required

If fire continues or source is unkown:

  • Cabin/doors/vents/ECS
    • Close/Off, as required
  • Unnecessary Electrical equipment and CBs
    • Secure

If fire continues:

  • Land as soon as possible
Term

Rescue Hoist Failure

Definition
  • Cease hoisting
  • Visually inspect hoist.
  • Verify:
    • Back-up Pump On advisory light
      • Illuminated
    • BACKUP HYD PMP switch
      • on
    • RESCUE HOIST switch
      • All
    • RESCUE HOIST CBs
      • In
        • RESCUE HOIST CTRL (NO.2 DC PRI)
        • RESCUE HOIST CTRL (NO.1 DC PRI)
  • Check normal hoist operations

If electrical failure persists:

  • BACKUP CONTROL
    • Select
  • Attempt to set personnel/cargo on deck/water

If unable:

  • Cable Grip
    • Rig
Term

Runaway Hoist

Definition
  • BACKUP CONTROL
    • Select

If payout continues:

  • Hydraulic pump
    • Secure
Term

Rescue Hoist Fouled Cable

Definition
  • Payout cable and attempt to free hangup.

If unable:

  • Cut/shear cable
    • as required
Term
Rescue Hoist Cable Cut
Definition
  • Emergency shear switch
    • SHEAR

If unable:

  • Direct pilot to press EMER REL button
Term
ASQ-81 Towed Body Down Limit Swith Malfunction
Definition
  • If no cable limit light within 61 seconds
    • Cease MAD reeling operations
  • Alert crew
  • REEL
    • IN
Term
M60D/M240D Fail to Fire/Jammed Gun
Definition
  • Barrel
    • safe direction
  • Wait 5 seconds
  • Charge handle
    • retract and lock
  • Safety
    • to SAFE
  • Chamber
    • inspect and clear
Term
M60D/M240D Runaway Gun
Definition
  • Barrel
    • safe direction
  • Ammo Belt
    • break by twisting

If weapon does not stop firing:

  • continue pointing in safe direction until ammo is expended.
  • Chamber
    • inspect and clear
  • Weapon status
    • report
Term
M60D/M240D Cookoff
Definition
  • Barrel
    • safe direction
  • Weapon
    • allow to cool (minimum 5 min.)
  • Chamber
    • Inspect
Term
GAU-16/A Jammed Gun
Definition
  • Barrel
    • safe direction
  • Wait 5 seconds
  • Charging handle
    • charge once
  • Attempt to fire

If weapon does not fire:

  • Chamber/ T-slot
    • Inspect and clear
Term
Gau-16/A Runaway Gun
Definition
  • Barrel
    • safe direction
  • Charging handle
    • pull down
  • Feed tray cover
    • open
  • Ammo
    • remove
  • Feed tray cover
    • Close
  • Charging handle
    • charge once
  • Chamber/T-slot
    • inspect and clear
Term
GAU-16/A Cookoff
Definition
  • Barrel
    • safe direction
  • Weapon
    • Allow to cool (minimum 5 min.)
  • Chamber/T-slot
    • inspect and clear
Term
AN/PEQ-3 Uncommanded Lasing
Definition
  • AN/PEQ-3
    • OFF
  • AN/PEQ-3 lens cover
    • ON
  • Batteries
    • Remove
Term
FLIR Uncommanded Lasing
Definition
  • WEAPON SELECT (AN/ASQ-198)
    • OFF
  • MASTER ARM
    • verify SAFE
  • LASER
    • DISABLE

If lasing continues:

  • FLIR Power
    • OFF
  • FLIR CBs
    • pull
      • SO OVHD
        • FLIR AC
        • FLIR/HFSAC
        • FLIR HFS AC
Term
Sonobouy Lithium Battery Venting
Definition
  • Alert Crew; sonobouys
    • Jettison
  • Smoke and Fumes Elimination EP
    • Perform
Term
Smoke and Fumes Elimination
Definition
  • Airspeed
    • adjust, as required
  • Doors/windows/vents
    • open
  • Aircraft
    • yaw, as required
Term
Refueling Hose Jettison (HIFR)
Definition
  • T-handle pull (if applicable)
  • Hose Status
    • report

If hose fails to breakaway:

  • Quickly disengage the nozzle and grounding wire, then cut the hoist cable.
Supporting users have an ad free experience!