Loss of the running Charging Pump.
Start another pump
Restore letdown
Restore PZR level to program
Charging Pump cavitation.
Stop the pump
Ensure letdown isolates
VCT level the problem?
Yes – find a charging pump to vent and put in service or put 23 pump on RWST and shut down or put 13 pump in service and shut down
No
Channel failure
Yes – 2CV35 to manual Manual makeup
No – Manual makeup
See leak (below)
Failure of a Pressurizer level channel.
Manual control
Select operable channels
Restore heaters
Restore letdown
THEN take charging to Auto (never take PZR level to Auto with a mismatch)
Remove channel IAW SO.RPS-0003
Failure of a Volume Control Tank level channel.
2CV35 manual to VCT
Restore letdown
Manual makeup
Leak (if unisolable, go to AB.RC-0001)
Ensure letdown is isolated
Lower charging to minimum
Notify Rad Pro
Downstream of 2CV71?
Yes – close 2CV71 and 2CV73
No
Downstream of discharge valves 2CV55 or 2CV64?
Yes
Stop pump and close discharge valve
Initiate shutdown and cooldown
Align charging thru the BIT
Excess letdown if necessary
No
Between CCP and CV55?
Yes – switch to PDP (from RWST) and shutdown the Unit.
No – AB.RC-0001
|