Term
SBLC
Describe the level indicators. |
|
Definition
-Float: 1300-1600 gallons. -High level at 1575 gallons. -Low level at 1407 gallons. -Alarms on C-05. -Bubbler: 0-1700 gallons. -Alarm at 0 net (8.5" and 325 galls). -Also secures heaters at 649.5 gallons (25"). |
|
|
Term
SBLC
Describe the heaters temperature band and power supply. |
|
Definition
-Maintain 68-110F (75F optimal). -Powered by MCC-132. |
|
|
Term
SBLC
Describe the pumps, capacity and power supply. |
|
Definition
-Positive displacement pumps and motors. -28.5gpm (24 design). -Pump A MCC-133. -Pump B MCC-142. |
|
|
Term
SBLC
Describe the squib valve continuity setpoint and panel location. |
|
Definition
-Alarm on C-05. -Set at <.7A. |
|
|
Term
SBLC
Describe how to initiate and what happens upon SBLC initiation. |
|
Definition
-Can only initiate 1 side. -Blows squib valve. -Squib valve only blows if initiated from C-05. -Shuts RWCU MO-2397,2398, 2399. -Shuts Recirc system sample valves CV-2790, 2791. |
|
|
Term
SBLC
Describe the effects of a loss of instrument air. |
|
Definition
-Low-low indication. -Heaters shut off. |
|
|
Term
SBLC
Describe the effects of a loss of Y-20. |
|
Definition
-Lose red and green lights for both pumps. -Lose the XP-8 indication light. -Lose both squib valve ready lights. |
|
|
Term
SBLC
Describe the effects of a loss of Y-30. |
|
Definition
-Receive tank Hi/Lo alarm. -C-05 SBLC tank level low. -Pump discharge fails low on C-05. |
|
|