Term
T or F
With an increase of pressure, the latent heat content of one pound of steam will decrease? |
|
Definition
|
|
Term
T or F
An increase in pressure will cause the boiling temperature of a liquid to decrease? |
|
Definition
|
|
Term
T or F
It is possible to boil water at 78F? |
|
Definition
|
|
Term
T or F
When steam is superheating its pressure and temperature are increased? |
|
Definition
|
|
Term
T or F
The boiling and condensing temperature of water is the same at any given pressure? |
|
Definition
|
|
Term
T or F
The volume of one pound of steam at 100 psig is 4 cubic feet per pound |
|
Definition
|
|
Term
T or F
The latent heat content of one pound of steam at 20 psig is 983 Btu?
|
|
Definition
|
|
Term
T or F
The Boiling Temperature of water at 25 psia is 267F? |
|
Definition
|
|
Term
T or F
The condensing temperature of steam is 125psig at 212F |
|
Definition
|
|
Term
Heat that can be indicated with a thermometer is called?
|
|
Definition
|
|
Term
The type of heat that is absorbed or liberated when a substance undergoes a change of state is |
|
Definition
|
|
Term
Vaporization, which occurs below the boiling temperature and only at the surface of a liquid is? |
|
Definition
|
|
Term
Vaporization which occurs throughout a liquic, with bubbles of vapor breaking through the surface of the liquid is called |
|
Definition
|
|
Term
The instantaneous change of state from a liquid to a vapor which takes place when a liquid flows from a high to a low pressure area, withouth a corresponding drop in temperature, is called?
Boiling
Flashing
Evaporation
Superheating |
|
Definition
|
|
Term
T or F
A low-pressure steam boiler is designed to operate at pressures up to 30 psig? |
|
Definition
|
|
Term
T or F
In order to keep the float chamber of a low water cutoff clean it must be blown down on a regular basis? |
|
Definition
|
|
Term
T or F
In order to clean an electric probe low water cutoff it must be removed from the boiler? |
|
Definition
|
|
Term
T or F
The distance required between the bottom of the last steam carrying line and the boiler water line is known as the dry return? |
|
Definition
|
|
Term
T or F
Any return line that is located below the water line of a boiler is known as a wet return line? |
|
Definition
|
|
Term
T or F
The line that supplies seam directly to the heating units is called a dry supply? |
|
Definition
|
|
Term
T or F
The cutout pressure of an additive differential pressuretrol is ste by adding the cut in setting to the cutout setting? |
|
Definition
|
|
Term
T or F
A compound gage should NEVER be installed on a low pressure steam boiler? |
|
Definition
|
|
Term
The device that controls the pressure in a low pressure steam boiler is called a?
Pressuretrol
Aquastat
thermostat
thermocouple |
|
Definition
|
|
Term
The safety relief valve that is installed on a low pressure steam boiler opens when a boiler pressure reaches?
30psig and resets at 27psig
3psig and reseats at 1psig
15psig an reseats at 12psig
18psig and reseats at 15 psig |
|
Definition
15 psig and reseats at 12psig |
|
|
Term
A pipe siphon (pigtail) forms a water seal that prevents raw steam from entering and damaging?
Sight Glass
Safety Valve
Pressure Gauge
Hartford Loop |
|
Definition
|
|
Term
The two basic types of low water cut offs are
Float type and electric probe type
Float type and return type
Electric probe type and siphon type
Differential type and aquastat type |
|
Definition
Float type and Electric Probe type |
|
|
Term
The line that connects the steam header to a boiler return line is the
Steam Header
Hartford Loop
Drip Connection
Equalizing line |
|
Definition
|
|
Term
T or F
Automatic air vents open when system pressure is increased? |
|
Definition
|
|
Term
T or F
The tee for the main vent should be placed 3' from the last steam carrying main? |
|
Definition
|
|
Term
T or F
A 6" to 10" long pipe nipple should be installed between the top of the tee and the main vent? |
|
Definition
|
|
Term
T or F
The bottom of a steam header must be at least 12" above the boiler water line? |
|
Definition
False
It must be 24" above the boiler water line. |
|
|
Term
T or F
In a one pipe parallel flow steam heating system, the steam supply main should be pitched at least 1/2" for each 20' length of pipe distance? |
|
Definition
|
|
Term
The arrangement of the return piping on a steam boiler that would reduce the likelihood of a low water condition in the boiler is called a
Equalizer
Reverse return
Hartford loop
Wet return |
|
Definition
|
|
Term
The return that cannot contain air or steam is called a
Wet return
Dry return
Reverse return
Direct return |
|
Definition
|
|
Term
The return line that could contain air steam or water is called a
Wet return
Dry return
Reverse return
Direct return
|
|
Definition
|
|
Term
The "A" dimension, the length of pipe used to overcome the pressure drop in a one pipe gravity steam heating system should be?
14"
12"
28"
a close nipple
|
|
Definition
|
|
Term
Pockets of condensate in steam lines could result in
carryover
foaming
priming
water hammer |
|
Definition
|
|
Term
The device tha tprevents a vacuum from forming inside a one pipe gravity return steam heating system is a
check valve
steam trap
air vent
safety relief valve |
|
Definition
|
|
Term
The carryover of small particles of water into steam piping is known as
priming
foaming
spotting
trapping |
|
Definition
|
|
Term
The rapid flucuation of the water level in a boiler which is created by impurities on the surface of the water is called?
Priming
Foaming
Spotting
Trapping |
|
Definition
|
|
Term
Steam flow into the radiators in a one pipe gravity return steam heating system can be controlled by?
Adjusting the radiator valve
Adjusting the pressuretrol
Adjusting the boiler firing rate
Installing an air vent with a different venting capacity |
|
Definition
Installing an air vent with a different venting capacity |
|
|
Term
The main vent in a one pipe gravity return steam heating system should be located ____ to ____ inches from the end of the last steam carrying main. |
|
Definition
|
|
Term
T or F
Installed correctly, the discharge from a thermostatic steam trap is not subject to freeze up problems? |
|
Definition
|
|
Term
T or F
Under normal operation, air and condensate are discharged from a float and thermostatic trap through the same orifice? |
|
Definition
|
|
Term
T or F
Thermodynamic steam traps operate due to the difference in teh thermal energy or heat content between the steam and the condensate? |
|
Definition
|
|
Term
T or F
The discharge of condensate from an inverted bucket steam trap is continuous?
|
|
Definition
|
|
Term
T or F
A thermostatic steam trap discharges condensate as soon as it enters the trap? |
|
Definition
|
|
Term
T or F
An inverted bucket steam trap should be installed if a large amount of air must be quickly removed from a steam system? |
|
Definition
|
|
Term
Thermostatic traps are opened and closed by a (an)
Float
Inverted bucket
Electric sensor
Flexible bellows |
|
Definition
|
|
Term
In a float and thermostatic trap the float rises to discharge?
Condensate
Air and Steam
Air
Steam |
|
Definition
|
|
Term
A thermostatic trap that failed in the closed position would cause a heating unit to become?
Steambound
Waterlogged
Superheated
Airbound |
|
Definition
|
|
Term
Condensate in steam lines could result in?
Water Hammer
Priming
Foaming
Carryover |
|
Definition
|
|
Term
Steam traps remove ______ and _____ from steam lines?
|
|
Definition
|
|
Term
The type of traps normally used on steam radiators are?
F&T Traps
Disc Traps
Inverted bucket traps
Thermostatic traps |
|
Definition
|
|
Term
In order to return condensate to a boiler, the height of the water column needed to overcome the pressure drop in a two pipe gravity return system is?
28"
28" for each pound of pressure the boiler is producing
2" to 4"
15" to 18" |
|
Definition
28 " for each lb of pressure the boiler is producing |
|
|
Term
Air is eliminated from a two pipe gravity return steam heating system by a
Vacuum pump
condensate receiver vent
Boiler feed pump vent
Main vent |
|
Definition
|
|
Term
In a two pipe gravity return system, the device that prevents raw steam from entering the condensate return piping is a:
Hartford loop
Dry return
Main vent
Steam trap |
|
Definition
|
|
Term
A _____ is used to protect condensate pumps from dirt, slag, etc...
|
|
Definition
|
|
Term
The pump motor on a condensate receiver is usually started by
a low water condition in the boiler
a high water condition in the boiler
a high water level in the reciever
a time clock |
|
Definition
a high water level in the reciever |
|
|
Term
The pump motor on a boiler feed pump is started when there is
A low water condition in the boiler
A high water condition in the boiler
A high water condition in the boiler feed pump reciever
A time clock
|
|
Definition
A low water condition in the boiler |
|
|
Term
Water is usually supplied to the boilers that are installed in large commercial systems or to a system with a condensate return problem or to fire tube boilers by a:
Condensate receiver pump
Boiler feed pump
Boiler return trap
Gravity return feeder |
|
Definition
|
|
Term
The device that is used to regulate the discharge pressure of a condensate pump is a :
Check valve
Gate valve
Flow control valve
Plug cock |
|
Definition
|
|
Term
T or F
In a two pipe gravity return system you should trap return lines that are flowing to a condensate receiver. This is because a centrifugal pump is being used to return water to the boiler?
|
|
Definition
|
|
Term
T or F
The water level in a boiler feed pump receiver is mechanically maintained? |
|
Definition
|
|
Term
T or F
A low water cutoff is installed in the condensate receiver in order to protect the boiler feed pump? |
|
Definition
|
|
Term
T or F
When a condensate or boiler feed pump is installed in a two pipe gravity return steam system a main vent is no longer needed? |
|
Definition
|
|
Term
Steam flow into radiators in a two pipe gravity return steam heating system cannot be controled? |
|
Definition
|
|
Term
In a vacuum steam heating system, the device that actuates the vacuum pump when there is a lose of vacuum in the return piping is the?
Pressuretrol
Aquastat
Vacuum Switch
Thermostat |
|
Definition
|
|
Term
In a vacuum steam heating system, the device which prevents a higher vacuum from forming in the supply piping than the return piping is a/an?
Pressure reducing valve
Balancing valve
Steam trap
Equalizing line |
|
Definition
|
|
Term
The device which is incorporated into a vacuum steam heating system to protect the vacuum pump from creating too low a vacuum is a?
Relief valve
Control line
Vacuum switch
Vacuum breaker |
|
Definition
|
|
Term
The device which can be used to elevate condensate in a vacuum steam heatin system is a
Steam trap
Vacuum breaker
Lift Fitting
Control line |
|
Definition
|
|
Term
In a vapor steam heating system, condensate is returned to the boiler by means of
A vacuum pump
A condensate reciever
A boiler feed pump
Gravity |
|
Definition
|
|
Term
What forces condensate out of the boiler return trap in a vapor steam heating system?
Boiler feed pump
Steam
Condensate reciever
Vacuum pump |
|
Definition
|
|
Term
What constitutes the division points between the supply and return piping in a vapor steam heating system?
Boiler return trap
Check Valves
Steam traps
Air Eliminators |
|
Definition
|
|
Term
Air is eliminated from a vapor steam heating system by a/an?
Standard air vent
Boiler return trap
Air eliminator
Main vent |
|
Definition
|
|
Term
A _____ is used to control the steam pressure in vapor steam heating systems? |
|
Definition
|
|
Term
T or F
In a vapor steam heating system, circulation is dependent upon a vacuum pump? |
|
Definition
|
|
Term
T or F
In order to eliminate air from a vapor steam heating system, standard vents should be installed? |
|
Definition
|
|
Term
T or F
Steam can be circulated at temperatures below 212F in a vapor steam heating systems? |
|
Definition
|
|
Term
T or F
When pressure in a vapor steam heating system is decreased, each pound of steam will occupy more space? |
|
Definition
|
|
Term
The device which is used to maintain a pressure differential between the supply and return piping in a sub atmospheric steam heatin system is a
Pressure controller
Vaporstat
Differential controler
Control valve |
|
Definition
|
|
Term
Air is eliminated from a sub atmospheric steam heating system by a/an?
Air vent
Air eliminator
Vacuum pump
Air scoop |
|
Definition
|
|
Term
The device which takes continuous readings of heating conditions in a sub atmospheric steam heating system and the amount of heat being supplied is a
Thermostat
Vapor
Control panel
Control valve
|
|
Definition
|
|
Term
the device which controls the steam pressure on the steam supply side of a sub atmospheric steam heating system is a
Differential controller
Control valve
Heat balancer
Vacuum pump |
|
Definition
|
|
Term
T or F
In a sub atmospheric system there is never a pressure of less than one psig on the supply side of the system? |
|
Definition
|
|
Term
T or F
Thermodynamic steam traps are often used in sub atmospheric heating systems? |
|
Definition
|
|
Term
T or F
Is it possible to circulate 160F steam in teh supply piping in a variable bacuum steam heating system?
|
|
Definition
|
|
Term
T or F
A sub atmospheric steam system is so called because the pressures on the supply side, as well as the return side of the system, are usually operating below atmospheric pressure? |
|
Definition
|
|
Term
T or F
Because a vacuum pump is used in a sub atmospheric steam heating system, supply and return piping need not be pitched? |
|
Definition
|
|
Term
T or F
Steam mains should be pitched in the direction of flow? |
|
Definition
|
|
Term
T or F
Reducing the pipe size in a horizontal steam main requires the use of a concentric reducer? |
|
Definition
|
|
Term
T or F
Branch connections should always be connected to the bottom of a steam supply main? |
|
Definition
|
|
Term
T or F
Guides are not needed if a slip type expansion joint is installed in the steam piping? |
|
Definition
|
|
Term
T or F
A saddle is used to protect pipe insulation against damage caused by pipe movment? |
|
Definition
|
|
Term
T or F
Steam piping should be attached to supports (hangers, brackets, etc) in such a way that it cant move? |
|
Definition
|
|
Term
T or F
Unreamed system piping may cause water hammer? |
|
Definition
|
|
Term
T or F
When pipe is heated, its length and width are increased? |
|
Definition
|
|
Term
T or F
Steam mains, piping, etc...that are tied into a dry return must utilize a steam trap? |
|
Definition
|
|
Term
T or F
Swing joints should always be installed in a steam heting system in order to accommodate expansion of the piping? |
|
Definition
|
|
Term
Radiators are generally classified as ____ radiation |
|
Definition
|
|
Term
Elements mounted inside of _____ radiation units located inside of a building near the floor line and against the outside wall are now in common use. |
|
Definition
|
|
Term
A ______ is a heat transfer unit that gives off most of its heat by convection? |
|
Definition
|
|
Term
The modern _____ consists of a steam or hot water coil and a circulating fan. |
|
Definition
|
|
Term
There are two types of unit heaters, ____ and ____. |
|
Definition
|
|
Term
The control valve for a convector should be installed ____ the heating element of the convector to prevent accumulation of condensate in the supply end of the convector. |
|
Definition
|
|
Term
T or F
Piping serving radiation units on teh second floor of a building may not be run on the ceiling of the floor below? |
|
Definition
|
|
Term
T or F
The supply connections to a heating element may be made at the bottom, top, or at the end of an inlet header? |
|
Definition
|
|
Term
T or F
Unit heaters designed for overhead use can be hung from the supply piping? |
|
Definition
|
|
Term
List the three basic types of low pressure steam boilers
C__t Ir_n
F__e T_b_
W__e_ T__e |
|
Definition
Cast Iron
Fire Tube
Water tube |
|
|
Term
Steam boilers that are operated up to _____ are called low pressure boilers. |
|
Definition
|
|
Term
The _______ supplies water to a boiler at an appropriate temperature and pressure to maintain the steam cycle. |
|
Definition
|
|
Term
_________ fans are used to FORCE air into the combustion chamber of a boiler through the boiler and up the chimney |
|
Definition
|
|
Term
_____ and _____ boilers are two types of steel boilers |
|
Definition
|
|
Term
The basic design of a _____ is used in most packaged fire tube boilers |
|
Definition
|
|
Term
_____ tube boilers are not commonly used for low pressure steam applications |
|
Definition
|
|
Term
What are three major causes of low water in a steam boiler?
Ca__le___ or In_tt__tion
O___ Fi__g of Boi_e__
D__ect_ in a Sy____ |
|
Definition
Carelessness or inattention
Over firing of a boiler
Defects in a system |
|
|
Term
Name three general types of low water control devices according to action.
Aut____ic F__l C_to__
W__er M_ke U_
C__b_ |
|
Definition
Automatic Fuel Cutoff
Water Make up
Combo, fuel cutoff/water make up |
|
|
Term
On a boiler supplying process steam, where 100% of the condensate is not returned to the boiler, a seperate _____and a ______ should be used
B___er W___ Fe__
Se___ate L__ Wa___ C_to__ |
|
Definition
Boiler water feed
Seperate low water cut off |
|
|
Term
T or F
Low water control devices using the float linkage system are the only type allowed to be used on steam boilers? |
|
Definition
|
|
Term
T or F
A steam flow line may NEVER be taken out of the steam equalizing pipe of a water column? |
|
Definition
|
|
Term
T or F
Water can be added to a boiler by use of an electric water feeder that can be added to the feeders low water cut off? |
|
Definition
|
|
Term
T or F
A condensate pump and receiver are used to accumulate returned condensate and pump it to the boiler? |
|
Definition
|
|
Term
T or F
If to or more boilers are installed in a single system it is necessary to install a mechanical means to maintain proper water lines in each boiler? |
|
Definition
|
|
Term
T or F
A mechanical water feeder must be installed on a boiler that is supplied by a boiler feed pump? |
|
Definition
|
|