TH-67 Electrical Systerms
ELO #3
14
Other
Professional
05/08/2011

Additional Other Flashcards

 


 

Cards

Term
How many direct current power sources are available for normal operations in the IFR configuration?
Definition
There are three DC power sources (main generator, stand-by generator, and main battery) available for normal operations in the IFR configuration.
Term
What is the rating of the main generator?
Definition
The main generator is rated at 28 VDC
Term
What is the rating of the stand-by generator?
Definition
The stand-by generator is rated at 28 VDC and 15 amperes.
Term
What is the rating of the main battery in the nose of the helicopter?
Definition
The main battery is rated at 24 VDC and 17 amperes.
Term
What does the Voltage Monitoring System allow the pilot to monitor?
Definition
The Voltage Monitoring System allows the pilot to monitor generators, batteries, and buss bars voltage.
Term
What does an inverter do?
Definition
An inverter converts direct current voltage to 115 volts alternating current (AC) to run two elements of the avionics package.
Term
What is the rating of the stand-by battery?
Definition
The stand-by battery is rated at 24 VDC.
Term
How many buss bars are there in the IFR configuration?
Definition
There are three buss bars (ESS 1, ESS 2, and NON-ESS) in the IFR configuration.
Term
Which buss bar is the most protected?
Definition
The pilot's buss bar (ESS 1) is the most protected buss bar.
Term
Following the main generator's failure (MAIN GEN FAIL) what powers the ESS 2 buss bar?
Definition
The main battery powers the ESS 2 buss bar in the event of the main generator's failure.
Term
Following a main generator failure (MAIN GEN FAIL) what powers the NON ESS buss bar?
Definition
The main battery powers the NON ESS buss bar provided the NON ESS switch is placed in the manual position; otherwise the NON ESS circuits are shed from the battery's load.
Term
In the IFR configuration, how many power sources are there for starting?
Definition
There are two power sources (main battery and auxiliary power unit) for starting.
Term
In the event of a dual generator failure (MAIN GEN FAIL and STBY GEN FAIL) and main battery power becomes depleted, what powers the stand-by attitude indicator?
Definition
The stand-by battery powers the stand-by attitude indicator for at least 30 minutes.
Term
What airspeed should be avoided when the stand-by generator is powering the ESS 1 buss bar?
Definition
Airspeed below 50 KIAS should be avoided for prolonged operation when the stand-by generator is providing power to the ESS 1 buss bar.