Term
|
Definition
phototimer and ionization chamber |
|
|
Term
|
Definition
Automatic Exposure Control System |
|
|
Term
What are 2 types of technique charts |
|
Definition
|
|
Term
Why is fixed kVp technique chart used more |
|
Definition
most control of contrast levels |
|
|
Term
|
Definition
|
|
Term
|
Definition
fuzziness or blurriness of the outline of the image |
|
|
Term
3 major classes of detail |
|
Definition
Motion, Material, Geometric |
|
|
Term
|
Definition
|
|
Term
|
Definition
Voluntary, involuntary and accidental |
|
|
Term
3 types of material factors |
|
Definition
Film, screen and good film/screen contact |
|
|
Term
|
Definition
|
|
Term
What causes size distortion aka magnification |
|
Definition
|
|
Term
What causes shape distortion |
|
Definition
Tube angulation and body angulation when unecessary |
|
|
Term
Do you get elongation or foreshortening with tube angulation |
|
Definition
|
|
Term
What do you get with body angulation elongation or foreshortening |
|
Definition
|
|
Term
If it is impossible to position a part close the film what has to be increased |
|
Definition
|
|
Term
In order to produce a radiograph having the best detail a technician should use what type of screen speed |
|
Definition
Slow CaWo4 (calcium tungstate) |
|
|
Term
If the part to be radio-graphed is positioned so that it is not parallel to the film it will be |
|
Definition
|
|
Term
The value of a small focal spot is that it helps to provide |
|
Definition
|
|
Term
Short exposures and immobilization of the body part are used to control |
|
Definition
involuntary motion and sharpness |
|
|
Term
what has the worst affect on detail |
|
Definition
|
|
Term
Radio-graphic detail refers to |
|
Definition
|
|
Term
misrepresentation of the true size or shape of an object is called |
|
Definition
|
|
Term
high speed intensifying screens allow for a short xposure time but sacrifice |
|
Definition
|
|
Term
To reduce motion a technician can |
|
Definition
communicate to the pt, use sand bags to immobilize pt and use short exposure time |
|
|
Term
what is the major cause of increased magnification |
|
Definition
|
|
Term
Warped cassettes, worn felt in cassettes, or damaged latches cold be the cause of |
|
Definition
|
|
Term
Grid radius effects recorded detail: true or false |
|
Definition
|
|
Term
Plastic or aluminum wedge filters are examples of |
|
Definition
compensating filters to provide uniform density |
|
|
Term
what % of time a technician must make changes in the technical factors |
|
Definition
|
|
Term
What is the purpose of a compensating filter |
|
Definition
to provide uniform density |
|
|
Term
What causes the most repeated radiographs in a radiology department |
|
Definition
over exposure and under exposure |
|
|
Term
|
Definition
tool used to measure pt part thickness |
|
|
Term
According to the xray syllabus on radiation protection the head of the patient should be at the anode size for |
|
Definition
|
|
Term
what screen speed and fss results in the best radiographic detail |
|
Definition
|
|
Term
a properly designed technique chart should be based on |
|
Definition
|
|
Term
true or false penumbra is distortion |
|
Definition
|
|
Term
Def: stretching of anatomy |
|
Definition
|
|
Term
def: misrepresentations of true size and shape of anatomy on film |
|
Definition
|
|
Term
def: main controlling factor of density |
|
Definition
|
|
Term
def: clarity and sharpness of anatomy on a radiograph |
|
Definition
|
|
Term
unsharpness around the true image |
|
Definition
|
|
Term
|
Definition
|
|
Term
size distortion is known as |
|
Definition
|
|
Term
main controlling factor of magnification |
|
Definition
|
|
Term
main controlling factor of contrast |
|
Definition
|
|
Term
describe what is meant by poor film screen contact |
|
Definition
|
|
Term
poor film screen contact causes what artifacts |
|
Definition
|
|
Term
the central ray is not directed to the center of the film what kind of distortion would u get |
|
Definition
|
|
Term
Recorded detail can be measured and is expressed as: |
|
Definition
|
|
Term
A resolution pattern will do what: |
|
Definition
measure and record line pairs per mm |
|
|
Term
what is recorded detail defined as |
|
Definition
accuracy of structural lines recorded |
|
|
Term
the relationship between focal spot size and distance results in |
|
Definition
|
|
Term
|
Definition
|
|
Term
|
Definition
increased recorded detail |
|
|
Term
the ability of the imaging system to distinguish between 2 adjacent structures defines |
|
Definition
|
|
Term
what is the equation for making your own chart |
|
Definition
body in CM x 2 + 30 and has to be over 44 kVp |
|
|
Term
what 2 conditions must be met before technique charts can be affective? |
|
Definition
xray equip. must be calibrated and image processing must be consistent through department |
|
|
Term
def:kVp value that is high enough to ensure penetration of the part but not too high to diminish radiographic detail |
|
Definition
|
|
Term
Def: pre-established guidelines used to select standardized exposure factors |
|
Definition
|
|
Term
what is the primary patient factor that determines the selection of exposure factors |
|
Definition
|
|
Term
what is the primary goal of exposure technique charts |
|
Definition
consistently produce quality images |
|
|
Term
what is an advantage of a fixed kVp technique |
|
Definition
|
|
Term
what is disadvantage of variable kVp technique chart |
|
Definition
increases heat load on xray tube |
|
|